商品編號: Belden-8723
Belden 8723 Awg22 x2Pair Audio, Control and Instrumentation Cable 廣播聲音音響, 儀表電腦控制電纜
22 AWG stranded (7x30) tinned copper conductors, polypropylene insulation, twisted pairs, individually Beldfoil® shielded (100% coverage), 24 AWG stranded tinned copper drain wire, PVC jacket.
8723
 |
|
Multi-Conductor - Shielded Twisted Pair Cable
22 AWG stranded (7x30) tinned copper conductors, polypropylene insulation, twisted pairs, individually Beldfoil® shielded (100% coverage), 24 AWG stranded tinned copper drain wire, PVC jacket. |
For more Information
please call
1-800-Belden1 |
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
8723 060U1000 |
1,000 FT |
19.000 LB |
CHROME |
|
2 SH PR #22 PP PVC |
8723 060U2000 |
2,000 FT |
36.000 LB |
CHROME |
|
2 SH PR #22 PP PVC |
8723 060U500 |
500 FT |
10.000 LB |
CHROME |
|
2 SH PR #22 PP PVC |
8723 060100 |
100 FT |
3.200 LB |
CHROME |
|
2 SH PR #22 PP PVC |
8723 0601000 |
1,000 FT |
19.000 LB |
CHROME |
C |
2 SH PR #22 PP PVC |
8723 06010000 |
10,000 FT |
190.000 LB |
CHROME |
C Y |
2 SH PR #22 PP PVC |
8723 0601640 |
1,640 FT |
32.800 LB |
CHROME |
|
2 SH PR #22 PP PVC |
8723 0602000 |
2,000 FT |
40.000 LB |
CHROME |
C |
2 SH PR #22 PP PVC |
8723 0603280 |
3,280 FT |
62.320 LB |
CHROME |
C |
2 SH PR #22 PP PVC |
8723 060500 |
500 FT |
9.500 LB |
CHROME |
|
2 SH PR #22 PP PVC |
8723 0605000 |
5,000 FT |
90.000 LB |
CHROME |
C |
2 SH PR #22 PP PVC |
8723 0609999 |
10,000 FT |
190.000 LB |
CHROME |
C Y |
2 SH PR #22 PP PVC |
|
Notes: |
|
C = CRATE REEL PUT-UP.
Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'.
|
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs |
AWG |
Stranding |
Conductor Material |
2 |
22 |
7x30 |
TC - Tinned Copper |
|
Insulation
Insulation Material:
Insulation Material |
PP - Polypropylene |
|
Inner Shield
Inner Shield Material:
Inner Shield Trade Name |
Type |
Inner Shield Material |
Coverage (%) |
Beldfoil® (Z-Fold®) |
Tape |
Aluminum Foil-Polyester Tape |
100 |
|
Inner Shield Drain Wire AWG:
Inner Shield Drain Wire Stranding: |
7x32 |
Inner Shield Drain Wire Conductor Material: |
TC - Tinned Copper |
Outer Shield
Outer Shield Material:
Outer Shield Material |
Unshielded |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
PVC - Polyvinyl Chloride |
|
Overall Cabling
Overall Nominal Diameter: |
0.160 in. |
Pair
Pair Color Code Chart:
Number |
Color |
1 |
Red & Black |
2 |
Green & White |
|
Pair Lay Length & Direction:
Lay Length (in.) |
Twists/ft. (twist/ft) |
1.500 |
8.000 |
|
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-30°C To +60°C |
UL Temperature Rating: |
60°C |
Bulk Cable Weight: |
18.300 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
42 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
1.600 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CM |
CEC/C(UL) Specification: |
CM |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
UL Flame Test: |
UL1685 UL Loading |
Plenum/Non-Plenum
Plenum Number: |
82723, 87723, 88723 |
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft) |
33.000 |
|
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
14.7 |
|
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: |
15 Ohm/1000 ft |
Max. Operating Voltage - UL:
Max. Recommended Current:
Current |
2.3 Amps per conductor @ 25°C |
|
|