8775  | | Multi-Conductor - CM Rated Cable 22 AWG stranded (7x30) tinned copper conductor, polypropylene insulation, twisted pairs individually shielded with Beldfoil® (100% coverage), overall PVC jacket and 22 AWG stranded tinned copper drain wire. | For more Information please call 1-800-Belden1 |
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 8775 060100 | 100 FT | 13.100 LB | CHROME | C | 11 FS PR #22 PP PVC | 8775 0601000 | 1,000 FT | 125.000 LB | CHROME | C | 11 FS PR #22 PP PVC | 8775 060500 | 500 FT | 63.000 LB | CHROME | C | 11 FS PR #22 PP PVC | |
Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs | AWG | Stranding | Conductor Material | Dia. (in.) | 11 | 22 | 7x30 | TC - Tinned Copper | .030 | |
Insulation
Insulation Material:
Insulation Material | Dia. (in.) | PP - Polypropylene | .050 | |
Inner Shield
Inner Shield Material:
Inner Shield Trade Name | Type | Inner Shield Material | Coverage (%) | Beldfoil® (Z-Fold®) | Tape | Aluminum Foil-Polyester Tape | 100 | |
Inner Shield Drain Wire AWG:
Inner Shield Drain Wire Stranding: | Stranded |
Inner Shield Drain Wire Conductor Material: | TC - Tinned Copper |
Outer Shield
Outer Shield Material:
Outer Shield Material | Unshielded | |
Outer Jacket
Outer Jacket Material:
Outer Jacket Material | PVC - Polyvinyl Chloride | |
Overall Cabling
Overall Nominal Diameter: | 0.464 in. |
Pair
Pair Color Code Chart:
Number | Color | 1 | Black & Red | 2 | Black & White | 3 | Black & Green | 4 | Black & Blue | 5 | Black & Yellow | 6 | Black & Brown | 7 | Black & Orange | 8 | Red & White | 9 | Red & Green | 10 | Red & Blue | 11 | Red & Yellow | |
Pair Lay Length & Direction:
Lay Length (in.) | Twists/ft. (twist/ft) | 1.750 | 6.850 | |
Mechanical Characteristics (Overall)
Operating Temperature Range: | -20°C To +80°C |
UL Temperature Rating: | 80°C (UL AWM Style 2919) |
Bulk Cable Weight: | 124.300 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 256 lbs. |
Min. Bend Radius (Install)/Minor Axis: | 4.600 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: | CM |
CEC/C(UL) Specification: | CM |
AWM Specification: | UL Style 2919 (30 V 80°C) |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test
UL Flame Test: | UL1685 UL Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 15 | |
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: | 10.600 Ohm/1000 ft |
Max. Operating Voltage - UL:
Voltage | 30 V RMS (UL AWM Style 2919) | 300 V RMS (CM) | |
Max. Recommended Current:
Current | 1.4 Amps per conductor @ 25°C | |