1856B
 |
|
Coax - RG-59/U Type
20 AWG solid .032" bare copper conductor, gas-injected foam HDPE insulation, bare copper braid shields (95% coverage), Belflex® jacket. |
For more Information
please call
1-800-Belden1 |
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
1856B B591000 |
1,000 FT |
86.000 LB |
BLACK, MATTE |
C |
#20 PE/GIFHDLDPE SH PVC TRIAX |
1856B 0021000 |
1,000 FT |
86.000 LB |
RED |
C |
#20 PE/GIFHDLDPE SH PVC TRIAX |
1856B 0041000 |
1,000 FT |
86.000 LB |
YELLOW |
C |
#20 PE/GIFHDLDPE SH PVC TRIAX |
1856B 0051000 |
1,000 FT |
86.000 LB |
GREEN, DARK |
C |
#20 PE/GIFHDLDPE SH PVC TRIAX |
1856B 0061000 |
1,000 FT |
86.000 LB |
BLUE, LIGHT |
C |
#20 PE/GIFHDLDPE SH PVC TRIAX |
1856B 0071000 |
1,000 FT |
86.000 LB |
VIOLET |
C |
#20 PE/GIFHDLDPE SH PVC TRIAX |
|
Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical Characteristics (Overall)
Conductor
AWG:
# Coax |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
1 |
20 |
Solid |
BC - Bare Copper |
.032 |
|
Insulation
Insulation Material:
Insulation Material |
Dia. (in.) |
Gas-injected FHDPE - Foam High Density Polyethylene |
.145 |
|
Inner Shield
Inner Shield Material:
Type |
Inner Shield Material |
Coverage (%) |
Braid |
BC - Bare Copper |
95 |
|
Inner Jacket
Inner Jacket Material:
Inner Jacket Material |
Nom. Dia. (in.) |
PVC - Polyvinyl Chloride |
.216 |
|
Outer Shield
Outer Shield Material:
Type |
Outer Shield Material |
Coverage (%) |
Braid |
BC - Bare Copper |
95 |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name |
Outer Jacket Material |
Belflex® |
PVC Blend - Polyvinyl Chloride Blend |
|
Overall Cabling
Overall Nominal Diameter: |
0.360 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-35°C To +75°C |
UL Temperature Rating: |
60°C |
Non-UL Temperature Rating: |
75°C |
Bulk Cable Weight: |
81 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
124 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
4.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CMR |
CEC/C(UL) Specification: |
CMG |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
UL Flame Test: |
UL1666 Vertical Shaft |
Suitability
Suitability - Indoor: |
Yes |
Suitability - Outdoor: |
Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
10.1 |
|
Nom. Inner Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
2.5 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
1.6 |
|
Nom. Attenuation:
Freq. (MHz) |
Attenuation (dB/100 ft.) |
1 |
.3 |
3.6 |
.6 |
10 |
.8 |
71.5 |
2.2 |
135 |
3.0 |
270 |
4.2 |
360 |
4.8 |
540 |
5.9 |
720 |
6.9 |
750 |
7.1 |
1000 |
8.8 |
1500 |
12.0 |
2250 |
16.4 |
3000 |
20.4 |
|
Max. Operating Voltage - UL:
Max. Operating Voltage - Non-UL:
Minimum Structural Return Loss:
Start Freq. (MHz) |
Stop Freq. (MHz) |
Min. SRL (dB) |
5 |
850 |
21 |
851 |
3000 |
15 |
|
Sweep Test
Sweep Testing: |
100% Sweep tested 5 MHz to 3 GHz. |