88232
 | | Coax - RG-59/U Type 20 AWG solid .032" bare copper conductor, plenum, foam FEP insulation, bare copper braid shields (95% coverage), FEP jacket. | For more Information please call
1-800-Belden1 |
| Item # | Putup | Ship Weight | Color | Notes | Item Desc | | 88232 0101000 | 1,000 FT | 62.000 LB | BLACK | C | #20 TRIAX FFEP RG59/U TYPE | | 88232 010500 | 500 FT | 29.000 LB | BLACK | C | #20 TRIAX FFEP RG59/U TYPE |
|
| Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
| # Coax | AWG | Stranding | Conductor Material | Dia. (in.) | | 1 | 20 | Solid | BC - Bare Copper | .032 |
|
Insulation
Insulation Material:
| Insulation Material | Dia. (in.) | | FFEP - Foam Fluorinated Ethylene Propylene | .140 |
|
Inner Shield
Inner Shield Material:
| Type | Inner Shield Material | Coverage (%) | | Braid | BC - Bare Copper | 95 |
|
Inner Jacket
Inner Jacket Material:
| Inner Jacket Material | Nom. Dia. (in.) | | FEP - Fluorinated Ethylene Propylene | .188 |
|
Outer Shield
Outer Shield Material:
| Type | Outer Shield Material | Coverage (%) | | Braid | BC - Bare Copper | 95 |
|
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material | | FEP - Fluorinated Ethylene Propylene |
|
Overall Cabling
| Overall Nominal Diameter: | 0.245 in. |
Mechanical Characteristics (Overall)
| Operating Temperature Range: | -40°C To +200°C |
| UL Temperature Rating: | 200°C |
| Non-UL Temperature Rating: | 200°C |
| Bulk Cable Weight: | 58 lbs/1000 ft. |
| Max. Recommended Pulling Tension: | 140 lbs. |
| Min. Bend Radius (Install)/Minor Axis: | 2.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: | CMP |
| CEC/C(UL) Specification: | CMP |
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2002/95/EC (RoHS): | Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): | 04/01/2005 |
| EU Directive 2002/96/EC (WEEE): | Yes |
| EU Directive 2003/11/EC (BFR): | Yes |
| CA Prop 65 (CJ for Wire & Cable): | Yes |
| MII Order #39 (China RoHS): | Yes |
Flame Test
Suitability
| Suitability - Outdoor: | Yes |
| Suitability - Aerial: | Yes - When supported by a messenger wire |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 10.0 |
|
Nom. Inner Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 2.6 |
|
Nominal Outer Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 2.6 |
|
Nom. Attenuation:
| Freq. (MHz) | Attenuation (dB/100 ft.) | | 1 | 0.4 | | 3.6 | 0.6 | | 10 | 0.8 | | 71.5 | 2.2 | | 135 | 3.1 | | 270 | 4.5 | | 360 | 5.3 | | 540 | 6.6 | | 720 | 7.7 | | 750 | 7.9 | | 1000 | 9.4 | | 1500 | 12.1 | | 2250 | 15.6 | | 3000 | 18.7 |
|
Max. Operating Voltage - UL:
Minimum Structural Return Loss:
| Start Freq. (MHz) | Stop Freq. (MHz) | Min. SRL (dB) | | 5 | 850 | 21 | | 851 | 3000 | 15 |
|
Sweep Test