1859A
 |
|
Coax - RG-11/U Type
15 AWG stranded (19x27) .064" bare copper conductor, plenum, foam FEP insulation, bare copper braid shields (95% coverage), fluorocopolymer jacket. |
For more Information
please call
1-800-Belden1 |
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
1859A 0101000 |
1,000 FT |
134.000 LB |
BLACK |
C |
#15 FFEP BRD SLF BRD SLF |
1859A 010500 |
500 FT |
66.500 LB |
BLACK |
C |
#15 FFEP BRD SLF BRD SLF |
|
Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical Characteristics (Overall)
Conductor
AWG:
# Coax |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
1 |
15 |
19x27 |
BC - Bare Copper |
.064 |
|
Insulation
Insulation Material:
Insulation Trade Name |
Insulation Material |
Dia. (in.) |
Teflon® |
FFEP - Foam Fluorinated Ethylene Propylene |
.285 |
|
Inner Shield
Inner Shield Material:
Type |
Inner Shield Material |
Coverage (%) |
Braid |
BC - Bare Copper |
95 |
|
Inner Jacket
Inner Jacket Material:
Inner Jacket Material |
Nom. Dia. (in.) |
PVDF - Fluorocopolymer |
.350 |
|
Outer Shield
Outer Shield Material:
Type |
Outer Shield Material |
Coverage (%) |
Braid |
BC - Bare Copper |
87 |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
PVDF - Fluorocopolymer |
|
Overall Cabling
Overall Nominal Diameter: |
0.406 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: |
125°C |
Non-UL Temperature Rating: |
125°C |
Bulk Cable Weight: |
125 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
264 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
4 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CMP |
CEC/C(UL) Specification: |
CMP |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
04/01/2005 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
Suitability
Suitability - Indoor: |
Yes |
Suitability - Outdoor: |
Yes |
Suitability - Aerial: |
Yes - when supported by messenger wire |
Suitability - Burial: |
Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
3.1 |
|
Nom. Inner Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
1.4 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
1.4 |
|
Nom. Attenuation:
Freq. (MHz) |
Attenuation (dB/100 ft.) |
1 |
0.1 |
3.6 |
0.2 |
10 |
0.5 |
71.5 |
1.3 |
135 |
1.9 |
270 |
3.0 |
360 |
3.6 |
540 |
4.5 |
720 |
5.4 |
750 |
5.6 |
1000 |
6.6 |
|
Max. Operating Voltage - UL:
Max. Operating Voltage - Non-UL:
Minimum Return Loss:
Description |
Freq. (MHz) |
Start Freq. (MHz) |
Stop Freq. (MHz) |
Min. RL (dB) |
|
|
5 |
850 |
21 |
|
Sweep Test
Sweep Testing: |
100% sweep tested 5 MHz to 850 MHz. |