9232
|
|
Coax - RG-11/U Type
15 AWG stranded (19x27) .064" bare copper conductor, foam HDPE insulation, paper tape separator, bare copper braid shields (90% coverage), Hypalon® jacket. |
For more Information
please call
1-800-Belden1 |
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
9232 0101000 |
1,000 FT |
145.000 LB |
BLACK |
C |
75 OHM TRIAX |
9232 010500 |
500 FT |
76.500 LB |
BLACK |
C |
75 OHM TRIAX |
|
Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical Characteristics (Overall)
Conductor
AWG:
# Coax |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
1 |
15 |
19x27 |
BC - Bare Copper |
.064 |
|
Insulation
Insulation Material:
Insulation Material |
Dia. (in.) |
Gas-injected FHDPE - Foam High Density Polyethylene |
.312 |
|
Inner Shield
Inner Shield Material:
Type |
Inner Shield Material |
Coverage (%) |
Braid |
BC - Bare Copper |
90 |
|
Inner Jacket
Inner Jacket Material:
Inner Jacket Material |
Nom. Dia. (in.) |
PE - Polyethylene |
.391 |
|
Outer Shield
Outer Shield Material:
Type |
Outer Shield Material |
Coverage (%) |
Braid |
BC - Bare Copper |
82 |
|
Outer Shield Separator Material: |
Paper Tape |
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name |
Outer Jacket Material |
Hypalon® |
Chlorosulphonated Polyethylene |
|
Overall Cabling
Overall Nominal Diameter: |
0.520 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-20°C To +75°C |
UL Temperature Rating: |
60°C |
Non-UL Temperature Rating: |
75°C |
Bulk Cable Weight: |
135 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
239 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
5.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
AWM Specification: |
UL Style 1641 (30 V 60°C) |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
UL Flame Test: |
UL1685 UL Loading, VW-1 |
Suitability
Suitability - Indoor: |
Yes |
Suitability - Outdoor: |
Yes |
Suitability - Burial: |
Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
3.1 |
|
Nom. Inner Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
1.6 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
1.6 |
|
Nom. Attenuation:
Freq. (MHz) |
Attenuation (dB/100 ft.) |
1.000 |
0.100 |
3.600 |
0.300 |
10.000 |
0.500 |
71.500 |
1.200 |
135.000 |
1.800 |
270.000 |
2.600 |
360.000 |
3.100 |
540.000 |
3.900 |
720.000 |
4.700 |
750.000 |
4.800 |
1000.000 |
5.700 |
|
Max. Operating Voltage - UL:
Max. Operating Voltage - Non-UL:
Other Electrical Characteristic 1: |
Nominal Capacitance 1st Shield to 2nd Shield: 205 pf/ft. |
Other Electrical Characteristic 2: |
Nominal Voltage Breakdown: 20K V RMS |
Minimum Return Loss:
Description |
Freq. (MHz) |
Start Freq. (MHz) |
Stop Freq. (MHz) |
Min. RL (dB) |
|
|
5 |
450 |
21 |
|
Sweep Test
Sweep Testing: |
100% sweep tested 5 MHz to 450 MHz. |
Misc. Information (Overall)
Notes (Overall)
Notes: |
Hypalon is a DuPont trademark. |