1. Belden- Belden® DataTuff® Cable
    Belden- Power Over Ethernet (POE) 以太網供電傳輸系統
    Belden- Solar & Wind Turbine Tray Cable太陽能 風力發電渦輪機用線
    Belden-Hirschmann™ Robust Unmanaged OCTOPUS Switch
    Belden-Industrial Fiber 工業級光纖電纜線
    Belden-Industrial Twinax Blue Hose® Cables
    Belden-Shipboard Audio Control and Instrumentation Cable
    Belden-工業( DeviceBus for ODVA DeviceNet™)用線
    Belden-工業(300V, Tray Cable)電線
    Belden-工業(600V,Tray Cable)電線
    Belden-工業(High-Temp/Thermocouple-Cable)高溫補償導線
    Belden-工業(Industrial Ethernet乙太網路)用線
    Belden-工業(Industry-PLC/DCS)用線
    Belden-工業(Thermocouple-Cable)補償導線
    Belden-工業(ULControl/Intrumentation)儀控用線
    Belden-工業InfinityFlex)用線
    Belden-工業RS-485用線
    Belden-工業-VFD(Variable Frequency Drive)變頻馬達控制用線
    Belden-工業級(Industrial Ethernet DataTuff® RJ45 Cord Set) 乙太網路跳接線
    Belden-工業級(Industrial Ethernet乙太網路)用線
    Belden-工業電腦(FOUNDATION Fieldbus or PROFIBUS Cable)用線
    Belden-工業電腦(PROFIBUS/Controlnet/QuadShielded Cable)用線
    Hirschmann-Ethernet Converters with Serial Interface
    Lumberg Automation™-Sensor Connectors
    Belden-MachFlex 350 Industrial Cables PVC工業級機械組裝電纜
    Belden-PROFINET Cable
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > Belden-工業電腦(FOUNDATION Fieldbus or PROFIBUS Cable)用線

    Belden3077F  1 Paired Awg22 - Type B  DataBus® ISA/SP-50 FOUNDATION Fieldbus Cable 300V 105°C 自動化工業電腦 FOUNDATION Fieldbus 控制訊號傳輸線
    看原圖
    468192

    Belden-3077F

    Belden-3077F  1 Paired Awg22 - Type B  DataBus® ISA/SP-50 FOUNDATION Fieldbus Cable 300V 105°C 自動化工業電腦 FOUNDATION Fieldbus 控制訊號傳輸線

    Industrial Data Solutions® — Industrial Data
    DataBus® ISA/SP-50 FOUNDATION Fieldbus or PROFIBUS Cables

    harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process
    automation, extreme temperature enviornments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.
    惡劣環境的數字和串行雙向通訊,油氣提取和提煉場所,石化,Profibus過程自動化或Foundation FieldBus過程
    自動化,極端溫度環境,暴露於濕氣,灰塵和油污,偏遠地區的長距離應用等。

    FHDPE Insulation • Orange PVC Jacket (Color Code: Blue, Orange)
    High Speed▲ 300V 105°C PLTC CM

    DESCRIPTION:
    22 AWG stranded (7x30) tinned copper conductors, polyolefin insulation, Beldfoil® shield (100% coverage), tinned copper drain wire, PVC jacket.


    PHYSICAL CHARACTERISTICS :


    CONDUCTOR :
    Number of Pairs: 1
    Total Number of Conductors: 2
    AWG: 22
    Stranding: 7x30
    Conductor Diameter: .030 in.
    Conductor Material: TC - Tinned Copper

    INSULATION :
    Insulation Material: PO - Polyolefin
    Lay Length: 1.50 in.
    Pair Color Code Chart:

    Number Color
    1 Blue & Orange



    OUTER SHIELD :
    Outer Shield Material Trade Name: Beldfoil®
    Outer Shield Type: Tape
    Outer Shield Material: Aluminum Foil-Polyester Tape
    Outer Shield %Coverage: 100 %

    OUTER SHIELD DRAIN WIRE :
    Outer Shield Drain Wire AWG: 20
    Outer Shield Drain Wire Stranding: 7x28
    Outer Shield Drain Wire Conductor Material: TC - Tinned Copper

    OUTER JACKET :

    Outer Jacket Material: PVC - Polyvinyl Chloride

    OVERALL NOMINAL DIAMETER :
    Overall Nominal Diameter: .196 in.
    MECHANICAL CHARACTERISTICS :

    Operating Temperature Range: -40°C To +105°C
    UL Temperature Rating: 105°C
    Bulk Cable Weight: 18 lbs/1000 ft.
    Max. Recommended Pulling Tension: 27 lbs.
    Min. Bend Radius (Install): 2.2 in.
    APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :


    APPLICABLE STANDARDS :
    NEC/(UL) Specification: PLTC, CM, ITC
    CEC/C(UL) Specification: CM
    EU CE Mark (Y/N): Yes
    EU RoHS Compliant (Y/N): Yes
    EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004

    FLAME TEST :
    UL Flame Test: UL1685 UL Loading

    PLENUM/NON-PLENUM :
    Plenum (Y/N): N
    ELECTRICAL CHARACTERISTICS :

    Unaveraged Impedance:

    Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Unaveraged Impedance (Ω)
    .03125 100


    Nom. Inductance: .20 µH/ft
    Nom. Capacitance Conductor to Shield @ 1 KHz: 44.0 pF/ft
    Nom. Mutual Capacitance @ 1 KHz: 23.5 pF/ft
    Maximum Capacitance Unbalance @ 1 KHz: 1.2 pF/ft
    Nominal Velocity of Propagation: 66 %
    Nom. Conductor DC Resistance @ 20 Deg. C: 17.1 Ω/1000 ft
    Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 11.4 Ω/1000 ft
    Nom. Attenuation (dB/100 ft):

    Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.)
    .039 .14


    Max. Attenuation (dB/100 ft.):

    Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Max. Attenuation (dB/100 ft.)
    .039 .152


    Max. Operating Voltage - UL: 300 V RMS
    Max. Recommended Current:

    Description Max. Recommended Current
    Per Conductor 2.5 Amps


    Other Electrical Characteristic 2: 31.25 KBits/sec
    NOTES :

    Notes: Tape around pair has shorting fold. CPE & LSOH Jacket optional.
    PUT-UPS AND COLORS:

    Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
    3077F 0031000 TWPR #22 PP FS PVC 1000 23 ORANGE C N
    3077F 003500 TWPR #22 PP FS PVC 500 11 ORANGE C N


    C = CRATE REEL PUT-UP.
    N = FINAL PUT-UP LENGTH MAY VARY -0% TO +10% FROM LENGTH SHOWN

    Fieldbus Specification
    IEC 61158-2 (ISA/SP-50)


    Fieldbus is an all-digital, serial, two-way
    communications protocol that standardizes
    the interconnection of field devices at a
    communications rate of 31.25 kB/s. The field
    devices are made accessible to communication
    networks (running at 1 or 2.5 Mb/s), through
    use of linking devices. Because a simple twisted
    pair of wires can carry the signals between the
    field devices and the networks, Fieldbus users can
    reduce the amount of I/O and control equipment
    (due to distribution of control into the field
    devices), plus they can use fewer Intrinsically
    Safe (IS) barriers, cabinets, cables and connectors.
    And, since the wire pair can support multiple
    functions within a single device (such as
    diagnostics, control and auto error correction),
    the twisted pair cable becomes the integral
    part of a more efficient, more reliable, and
    more cost-effective industrial control system.
     

    Why FOUNDATION Fieldbus?


    With FOUNDATION Fieldbus, end users have the
    freedom to implement tightly integrated digital
    control based on a unified system architecture
    and a high-speed backbone (HSE) for plant
    operations. This, in turn, removes the constraints
    on device and sub-system interoperability.
     

    Fieldbus Cabling Features


    The number of devices possible on a fieldbus link
    will vary depending on factors such as the power
    consumption of each device, the use of repeaters,
    signal attenuation, type of cable used and distance.
    The table below provides suggested transmission
    distances (cable lengths) for each type of cable.
    Because of the superior features of Belden
    DataBus cables, distance limitations can be
    exceeded without any system enhancements
    or any sacrifice in system performance.
    Belden Fieldbus cable features include:
    • Compliant with Fieldbus Spec IEC 61158-2
    (ISA/SP-50)
    • Excellent electrical characteristics
    • Low capacitance (for long runs)
    • Versions in 22, 18, 16 and 14 AWG stranded
    tinned copper conductors
    • Standard multi-pair cables available in 2 to 24
    pairs in 300V and LSZH or 600V designs
    • Versions available with Beldfoil® shields and
    Beldfoil Plus Braid shields
    • PLTC/ITC-ER, PLTC, and TC-ER versions available
    • Easily identifiable Orange jacket
    • Blue jacket available for
    Intrinsically Safe applications
    • Suitable for use in Class 1, Div. 2 applications
    • RoHS compliant and CE approved
    • CMX-Outdoor rated as listed

    Fieldbus High Speed Ethernet (HSE) Cables


    Fieldbus has chosen Ethernet for HSE control
    backbone 100Mb/s transmissions. To help you
    with your selection of Category 5e and Category 6
    cables, Belden offers its DataTuff® Industrial Ethernet
    Cable Selection Guide. For more information on
    Belden DataTuff cables, please call Belden or ask
    for the Industrial Ethernet New Product Bulletin.
    Custom Cable Constructions
    As always with Belden industrial cables,
     

    custom constructions are available:

    • Aluminum or Steel Interlocked Armor
    • CPE jacket or LSOH jacket
    • Various jacket colors
    • Alternate Black and White color-coded pairs
    • Multi-pair Type A, 300V, individually and
    overall shielded and PVC jacketed with up to
    50-pair capability
    • Multi-pair Type B 22 AWG, PLTC-rated,
    individually and/or overall shielded

    keywords: Belden3077F, FOUNDATION Fieldbus,Type B  DataBus, pltc, tcer