| | DESCRIPTION: 20 AWG pairs solid conductors, PVC insulation, individually shielded plus an overall Beldfoil shield (100% coverage), PVC jacket. PHYSICAL CHARACTERISTICS : CONDUCTOR : Number of Pairs: 4 Number of Conductors: 1 Total Number of Conductors: 9 AWG: 20, 22 Multi-Pairs/Conductors: Number of Pairs/Conductors AWG Stranding Conductor Material Conductor Diameter (in.) 2 Pairs 20 Solid Chromel 2 Pairs 20 Solid Constantan 1 Conductor 22 7x30 BC - Bare Copper Stranding: Solid, 7x30 Conductor Material: Chromel & Constantan, BC - Bare Copper INSULATION : Insulation Material: PVC - Polyvinyl Chloride Nom. Insulation Wall Thickness: .016 in. Lay Length: 2.5 in. Twists/ft.: 4.8 Pair Color Code Chart: Number Color 1 White & Red and Numbered 1 2 White & Red and Numbered 2 3 White & Red and Numbered 3 Number Color 4 White & Red and Numbered 4 INNER SHIELD : Inner Shield Material Trade Name: Beldfoil® Inner Shield Type: Tape Inner Shield Material: Aluminum Foil-Polyester Tape Inner Shield % Coverage: 100 % Inner Shield Drain Wire AWG: 22 Inner Shield Drain Wire Stranding: 7x30 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper OVERALL CABLING : Overall Cabling Lay Length: 5.9 in. OUTER SHIELD : Outer Shield Material Trade Name: Beldfoil® Outer Shield Type: Tape Outer Shield Material: Aluminum Foil-Polyester Tape Outer Shield %Coverage: 100 % OUTER SHIELD DRAIN WIRE : Outer Shield Drain Wire AWG: 20 Outer Shield Drain Wire Stranding: 7x28 Outer Shield Drain Wire Conductor Material: TC - Tinned Copper OUTER JACKET : Outer Jacket Material: PVC - Polyvinyl Chloride Outer Jacket Ripcord: Yes OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .383 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -30°C To +105°C Non-UL Temperature Rating: 105°C Bulk Cable Weight: 95 lbs/1000 ft. Max. Recommended Pulling Tension: 111 lbs. Min. Bend Radius (Install): 3.8 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CMG, PLTC, ITC CEC/C(UL) Specification: CMG CSA Specification: FT4 IEEE Specification: 1202 EU CE Mark (Y/N): Yes EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 04/01/2005 ANSI Specification: MC 96.1-1982 Type JX FLAME TEST : UL Flame Test: UL1685 FT4 Loading ICEA Flame Test: T-29-520 PLENUM/NON-PLENUM : Plenum (Y/N): N ELECTRICAL CHARACTERISTICS : Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 10.6 Ω/1000 ft Nominal Outer Shield DC Resistance @ 20 Deg. C: 6.8 Ω/1000 ft Max. Operating Voltage - Other: 300 V RMS NOTES : Notes: Chromel & Constantan = "Chromel is a Hoskins Manufacturing Company trademark." PUT-UPS AND COLORS: Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes 1006A 0105000 4 FSPR #20 + 1 #22 PVC FSPVCJX 5000 480 BLACK C Z
C = CRATE REEL PUT-UP. Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. |
| |
|
|