| 商品編號: Belden-183092A
Belden-183092A Continuously Corrugated AL Armor Quad Shielded Coax for ControlNet Applications 可直接埋設波浪狀鋁管鎧裝電纜
Belden® ControlBus cables are Low-loss RG-6/U Type Coaxes.They meet the high-speed, time-critical requirements necessary for the operation of ControlNet™ factory-floor systems. With a Continuously Corrugated Aluminum Armored Product |
| |
| | |
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
| |
| | |
| | 183092A  | | Coax - ControlNet® Quad Shielded Coax RG-6/U Type, 18 AWG solid bare copper-covered steel, foam Polyethylene insulation, Duobond® IV Quad Shield, inner PVC Jacket, continuously corrugated aluminum armor, outer PVC jacket. | For more Information please call 1-800-Belden1 | Item # | Putup | Ship Weight | Color | Notes | Item Desc | 183092A 0102000 | 2,000 FT | 306.000 LB | BLACK | C Z | ARMORED COAX PVC | | Notes: | | C = CRATE REEL PUT-UP. Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. | Usage (Overall) Suitable Applications: | Industrial Data Solutions®, Industrial Coax, ControlNet™ Quad Shielded Coax | Physical Characteristics (Overall) Conductor AWG: # Coax | AWG | Stranding | Conductor Material | Dia. (in.) | 1 | 18 | Solid | BCCS - Bare Copper Covered Steel | .040 | | Insulation Insulation Material: Insulation Material | Dia. (in.) | FPE - Foam Polyethylene | .180 | | Inner Jacket Inner Jacket Material: Inner Jacket Material | PVC - Polyvinyl Chloride | | Outer Shield Outer Shield Material: Layer # | Outer Shield Trade Name | Type | Outer Shield Material | Coverage (%) | 1 | Bonded Duofoil® | Tape | Bonded Aluminum Foil-Poly Tape-Aluminum Foil | 100 | 2 | | Braid | AL - Aluminum | 60 | 3 | Duofoil® | Tape | Aluminum Foil-Polyester Tape-Aluminum Foil | 100 | 4 | | Braid | AL - Aluminum | 40 | | Outer Jacket Outer Jacket Material: Outer Jacket Material | PVC - Polyvinyl Chloride | | Armor Armor Type: | Continuously Corrugated | Diameter over Armor: | .460 | Overall Cabling Overall Nominal Diameter: | 0.570 in. | Mechanical Characteristics (Overall) Operating Temperature Range: | -30°C To +75°C | Max. Recommended Pulling Tension: | 162 lbs. | Min. Bend Radius (Install)/Minor Axis: | 6.850 in. | Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: | CL2, CM | EU Directive 2000/53/EC (ELV): | Yes | EU Directive 2002/95/EC (RoHS): | Yes | EU RoHS Compliance Date (mm/dd/yyyy): | 10/1/2005 | EU Directive 2002/96/EC (WEEE): | Yes | EU Directive 2003/11/EC (BFR): | Yes | CA Prop 65 (CJ for Wire & Cable): | Yes | MII Order #39 (China RoHS): | Yes | Flame Test UL Flame Test: | UL1685 UL Loading | Suitability Suitability - Indoor: | Yes | Suitability - Outdoor: | Yes | Suitability - Burial: | Yes | Plenum/Non-Plenum Electrical Characteristics (Overall) Nom. Characteristic Impedance: Nom. Inductance: Nom. Capacitance Conductor to Shield: Nominal Velocity of Propagation: Nominal Delay: Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/1000 ft) | 28.0 | | Nominal Outer Shield DC Resistance: DCR @ 20°C (Ohm/1000 ft) | 3.6 | | Nom. Attenuation: Freq. (MHz) | Attenuation (dB/100 ft.) | 1 | .35 | 2 | .38 | 5 | .45 | 10 | .59 | 20 | .86 | 50 | 1.37 | 100 | 1.97 | 200 | 2.82 | 300 | 3.48 | 400 | 4.04 | | Minimum Structural Return Loss: Description | Freq. (MHz) | Start Freq. (MHz) | Stop Freq. (MHz) | Min. SRL (dB) | | | 5 | 50 | 23 | | |
| |
|
|