7712A
|
|
Coax - RG-6/U Type
RG-6/U type, 18 AWG solid .040” bare copper conductors, gas-injected foam HDPE insulation, Duofoil® + tinned copper braid shield (95% coverage), overall PVC jacket. |
For more Information
please call
1-800-Belden1 |
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
7712A B591000 |
1,000 FT |
454.000 LB |
BLACK, MATTE |
C |
5 #18 PE SH PVC FRTPE |
7712A B59500 |
500 FT |
216.500 LB |
BLACK, MATTE |
C |
5 #18 PE SH PVC FRTPE |
|
Notes: |
|
C = CRATE REEL PUT-UP.
|
Usage (Overall)
Suitable Applications: |
Video Mult. |
Physical Characteristics (Overall)
Conductor
AWG:
# Coax |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
5 |
18 |
Solid |
BC - Bare Copper |
.040 |
|
Insulation
Insulation Material:
Insulation Material |
Dia. (in.) |
Gas-injected FHDPE - Foam High Density Polyethylene |
.180 |
|
Inner Shield
Inner Shield Material:
Layer # |
Inner Shield Trade Name |
Type |
Inner Shield Material |
Coverage (%) |
1 |
Duofoil® |
Tape |
Aluminum Foil-Polyester Tape-Aluminum Foil |
100 |
2 |
|
Braid |
TC - Tinned Copper |
95 |
|
Inner Jacket
Inner Jacket Material:
Inner Jacket Material |
Nom. Dia. (in.) |
PVC - Polyvinyl Chloride |
.275 |
|
Inner Jacket Color Code Chart:
Number |
Color |
1 |
Red |
2 |
Green |
3 |
Blue |
4 |
White |
5 |
Yellow |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
PVC - Polyvinyl Chloride |
|
Overall Cabling
Overall Nominal Diameter: |
0.970 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-40°C To +75°C |
UL Temperature Rating: |
60°C |
Non-UL Temperature Rating: |
75°C |
Bulk Cable Weight: |
384 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
345 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
10 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CMR |
CEC/C(UL) Specification: |
CMG |
AWM Specification: |
UL Style 1354 (each coax); UL Style 2688 (overall) |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
UL Flame Test: |
UL1666 Vertical Shaft |
Suitability
Suitability - Indoor: |
Yes |
Suitability - Outdoor: |
Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
6.4 |
|
Nom. Inner Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
3.0 |
|
Nom. Attenuation:
Freq. (MHz) |
Attenuation (dB/100 ft.) |
1.000 |
0.240 |
3.580 |
0.440 |
5.000 |
0.520 |
7.000 |
0.610 |
10.000 |
0.710 |
67.500 |
1.650 |
71.500 |
1.690 |
88.500 |
1.860 |
100.000 |
1.950 |
135.000 |
2.240 |
143.000 |
2.300 |
180.000 |
2.570 |
270.000 |
3.170 |
360.000 |
3.690 |
540.000 |
4.600 |
720.000 |
5.380 |
750.000 |
5.500 |
1000.000 |
6.420 |
1500.000 |
7.990 |
2000.000 |
9.370 |
2250.000 |
10.010 |
3000.000 |
11.780 |
|
Max. Operating Voltage - UL:
Other Electrical Characteristic 1: |
Impedance tested in accordance with ASTM D-4566 paragraph 43.2, option 2 using a 75 Ohm fixed bridge and termination. |
Other Electrical Characteristic 2: |
Return Loss tested in accordance with ASTM D-4566 paragraph 45.3, using a 75 Ohm fixed bridge and termination. |
Minimum Structural Return Loss:
Start Freq. (MHz) |
Stop Freq. (MHz) |
Min. SRL (dB) |
5 |
440 |
23 |
440 |
520 |
15 |
520 |
850 |
23 |
851 |
3000 |
15 |
|
Sweep Test
Sweep Testing: |
Sweep tested 5 MHz to 3 GHz. |