商品編號: Belden-1819R
Belden-1819R 22 AWG 16Pair Analog Multi-Pair Snake Cable CMR Individually Shielded and Jacketed Twisted Pairs 多對型個別鋁箔隔離廣播音響纜線
22 AWG stranded (7x30) tinned copper conductor. Polyolefin
insulation. Twisted pairs individual bonded Beldfoil® shield and
have numbered and color-coded PVC jackets (see Chart 7 in
Technical Information Section for colors). Jackets and shields are
bonded so both strip simultaneously. Overall Beldfoil shield plus
overall Black PVC jacket and nylon rip cord.
1819R
|
|
Multi-Conductor - CMR Rated Cable
22 AWG stranded (7x30) TC conductor, polyolefin insulation, individually shielded with bonded Beldfoil®, numbered/color-coded PVC jackets, jackets and shields are bonded so both strip simultaneously, overall black PVC jacket and nylon rip cord. |
For more Information
please call
1-800-Belden1 |
Click here for Certificate
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
1819R 0101000 |
1,000 FT |
364.000 LB |
BLACK |
C |
16 #22 FS PR PVC FS PVC |
1819R 010500 |
500 FT |
177.000 LB |
BLACK |
C |
16 #22 FS PR PVC FS PVC |
|
Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
16 |
22 |
7x30 |
TC - Tinned Copper |
.030 |
|
Total Number of Conductors: |
32 |
Insulation
Insulation Material:
Insulation Material |
Dia. (in.) |
PO - Polyolefin |
.050 |
|
Inner Shield
Inner Shield Material:
Inner Shield Trade Name |
Type |
Inner Shield Material |
Coverage (%) |
Beldfoil® |
Tape |
Aluminum Foil-Polyester Tape |
100 |
|
Inner Shield Drain Wire AWG:
Inner Shield Drain Wire Stranding: |
7x30 |
Inner Shield Drain Wire Conductor Material: |
TC - Tinned Copper |
Inner Jacket
Inner Jacket Material:
Inner Jacket Material |
Nom. Dia. (in.) |
PVC - Polyvinyl Chloride |
.133 |
|
Outer Shield
Outer Shield Material:
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
Beldfoil® |
Tape |
Aluminum Foil-Polyester Tape |
100 |
|
Outer Shield Drain Wire AWG:
AWG |
Stranding |
Drain Wire Conductor Material |
18 |
19x30 |
TC - Tinned Copper |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
PVC - Polyvinyl Chloride |
|
Outer Jacket Ripcord: |
Yes |
Overall Cable
Overall Cabling Color Code Chart:
Number |
Color |
1 |
Brown |
2 |
Red |
3 |
Orange |
4 |
Yellow |
5 |
Green |
6 |
Blue |
7 |
Purple |
8 |
Gray |
9 |
White |
10 |
Black |
11 |
Tan |
12 |
Pink |
13 |
Lt Gray/Brown |
14 |
Lt Gray/Red |
15 |
Lt Gray/Orange |
16 |
Lt Gray/Yellow |
|
Overall Nominal Diameter: |
0.776 in. |
Pair
Pair Color Code Chart:
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-20°C To +60°C |
Bulk Cable Weight: |
339 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
461.500 lbs. |
Min. Bend Radius/Minor Axis: |
8 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CMR |
CEC/C(UL) Specification: |
CMG |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
UL Flame Test: |
UL1666 Riser |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
14.8 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
11.8 |
|
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: |
14.100 Ohm/1000 ft |
Max. Operating Voltage - UL:
Max. Recommended Current:
Current |
1.45 Amps per conductor @ 25°C |
|
Notes (Overall)
Notes: |
Pair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment. Beldfoil® provides high reliability with ease of termination. |
Test Reports
a) UL
i) UL Test Reports are available on-line through the UL Client Document Access web portal.
ii) UL Inspection Reports are also available through the UL Client Document Access web portal.
b) CSA
i) CSA "Descriptive Report and Test Results" documents are available on the CSA Gateway Portal.
ii) CSA Inspection Reports are maintained on the CSA issued flash drive at each manufacturing location.
* other test data may be available if requested at time of order.
|