88777
| | Multi-Conductor - CMP Rated (Plenum) Cable 22 AWG stranded (7x30) TC conductor, FEP insulation, twisted pairs individually shielded with Beldfoil® (100% coverage), overall jacket per table below, 22 AWG stranded TC drain wire. | For more Information please call
1-800-Belden1 |
Click here for Certificate
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 88777 002100 | 100 FT | 5.900 LB | RED | C | 3 SH PR #22 FEP FEP | 88777 0021000 | 1,000 FT | 41.000 LB | RED | C | 3 SH PR #22 FEP FEP | 88777 002500 | 500 FT | 20.000 LB | RED | C | 3 SH PR #22 FEP FEP |
|
Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs | AWG | Stranding | Conductor Material | Dia. (in.) | 3 | 22 | 7x30 | TC - Tinned Copper | .030 |
|
Total Number of Conductors: | 6 |
Insulation
Insulation Material:
Insulation Trade Name | Insulation Material | Wall Thickness (in.) | Teflon® | FEP - Fluorinated Ethylene Propylene | 0.010 |
|
Inner Shield
Inner Shield Material:
Inner Shield Trade Name | Type | Inner Shield Material | Coverage (%) | Beldfoil® (Z-Fold®) | Tape | Aluminum Foil-Polyester Tape | 100 |
|
Inner Shield Drain Wire AWG:
Inner Shield Drain Wire Stranding: | 16x34 |
Inner Shield Drain Wire Conductor Material: | TC - Tinned Copper |
Outer Shield
Outer Shield Material:
Outer Shield Material | Unshielded |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name | Outer Jacket Material | Nom. Wall Thickness (in.) | Teflon® | FEP - Fluorinated Ethylene Propylene | 0.014 |
|
Overall Cable
Overall Nominal Diameter: | 0.234 in. |
Pair
Pair Color Code Chart:
Number | Color | 1 | Black & Red | 2 | Black & White | 3 | Black & Green |
|
Mechanical Characteristics (Overall)
Operating Temperature Range: | -70°C To +200°C |
Bulk Cable Weight: | 37 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 82 lbs. |
Min. Bend Radius/Minor Axis: | 2.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: | CMP |
CEC/C(UL) Specification: | CMP |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 04/01/2005 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Maximum Conductor DC Resistance:
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: | 11.300 Ohm/1000 ft |
Max. Operating Voltage - UL:
Max. Recommended Current:
Current | 1.96 Amps per conductor @ 25°C |
|
Notes (Overall)
Notes: | Teflon® is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc. |
Test Reports
a) UL
i) UL Test Reports are available on-line through the UL Client Document Access web portal.
ii) UL Inspection Reports are also available through the UL Client Document Access web portal.
b) CSA
i) CSA "Descriptive Report and Test Results" documents are available on the CSA Gateway Portal.
ii) CSA Inspection Reports are maintained on the CSA issued flash drive at each manufacturing location.
* other test data may be available if requested at time of order.