9731 | | Multi-Conductor - Multi-Pair Snake Cable 24 AWG stranded (7x32) TC conductors, Datalene® insulation, twisted pairs, individually shielded w/Beldfoil® (100% coverage), 24 AWG stranded TC drain wire, overall PVC jacket. | For more Information please call 1-800-Belden1 |
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 9731 060100 | 100 FT | 7.400 LB | CHROME | C | 6 FS PR #24 FHDPE PVC | 9731 0601000 | 1,000 FT | 83.000 LB | CHROME | C | 6 FS PR #24 FHDPE PVC | 9731 060500 | 500 FT | 42.000 LB | CHROME | C | 6 FS PR #24 FHDPE PVC | |
Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs | AWG | Stranding | Conductor Material | Dia. (in.) | 6 | 24 | 7x32 | TC - Tinned Copper | .024 | |
Insulation
Insulation Material:
Insulation Trade Name | Insulation Material | Dia. (in.) | Datalene® | FPE - Foam Polyethylene | .061 | |
Inner Shield
Inner Shield Material:
Inner Shield Trade Name | Type | Inner Shield Material | Coverage (%) | Beldfoil® (Z-Fold®) | Tape | Aluminum Foil-Polyester Tape | 100 | |
Inner Shield Drain Wire AWG:
Inner Shield Drain Wire Stranding: | 7x32 |
Inner Shield Drain Wire Conductor Material: | TC - Tinned Copper |
Outer Jacket
Outer Jacket Material:
Outer Jacket Material | PVC - Polyvinyl Chloride | |
Overall Cabling
Overall Nominal Diameter: | 0.421 in. |
Pair
Pair Color Code Chart:
Number | Color | 1 | Black & Red | 2 | Black & White | 3 | Black & Green | 4 | Black & Blue | 5 | Black & Yellow | 6 | Black & Brown | |
Pair Lay Length & Direction:
Lay Length (in.) | Twists/ft. (twist/ft) | 1.700 | 6.850 | |
Mechanical Characteristics (Overall)
Operating Temperature Range: | -20°C To +80°C |
UL Temperature Rating: | 60°C (UL AWM Style 2493) |
Bulk Cable Weight: | 82 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 103 lbs. |
Min. Bend Radius (Install)/Minor Axis: | 4.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: | CM |
CEC/C(UL) Specification: | CM |
AWM Specification: | UL Style 2493 (300 V 60°C) |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test
UL Flame Test: | UL1685 UL Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 24 | |
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: | 15 Ohm/1000 ft |
Nom. Attenuation:
Freq. (MHz) | Attenuation (dB/100 ft.) | .384 | 0.74 | .7056 | 0.87 | .768 | 0.88 | 1.024 | 0.94 | 1.4112 | 1.01 | 1.536 | 1.03 | 2.048 | 1.13 | 2.8224 | 1.29 | 3.072 | 1.35 | 4.096 | 1.57 | 5.6448 | 1.78 | 6.144 | 1.84 | 8.192 | 2.13 | 11.2896 | 2.45 | 12.288 | 2.57 | 24.576 | 3.57 | |
Max. Operating Voltage - UL:
Voltage | 300 V RMS (UL AWM Style 2493) | |
Max. Recommended Current:
Current | 2.5 Amps per conductor @ 25°C | |
Notes (Overall)
Notes: | Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight. |