8102 | | Multi-Conductor - Low Capacitance Computer Cable for EIA RS-232/422 24 AWG stranded (7x32) TC conductors, Datalene® insulation, twisted pairs, overall Beldfoil® (100% coverage) + TC braid shield (65% coverage), 24 AWG stranded TC drain wire, PVC jacket | For more Information please call 1-800-Belden1 |
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 8102 060100 | 100 FT | 4.100 LB | CHROME | | 2 PR #24 FHDPE SH PVC | 8102 0601000 | 1,000 FT | 38.000 LB | CHROME | C | 2 PR #24 FHDPE SH PVC | 8102 06010000 | 10,000 FT | 380.000 LB | CHROME | C Y | 2 PR #24 FHDPE SH PVC | 8102 060500 | 500 FT | 17.000 LB | CHROME | C | 2 PR #24 FHDPE SH PVC | |
Notes: | |
C = CRATE REEL PUT-UP. Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'. |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs | AWG | Stranding | Conductor Material | 2 | 24 | 7x32 | TC - Tinned Copper | |
Insulation
Insulation Material:
Insulation Trade Name | Insulation Material | Datalene® | FPE - Foam Polyethylene | |
Outer Shield
Outer Shield Material:
Layer # | Outer Shield Trade Name | Type | Outer Shield Material | Coverage (%) | 1 | Beldfoil® | Tape | Aluminum Foil-Polyester Tape w/Shorting Fold | 100 | 2 | | Braid | TC - Tinned Copper | 65 | |
Outer Shield Drain Wire AWG:
AWG | Stranding | Drain Wire Conductor Material | 24 | 7x32 | TC - Tinned Copper | |
Outer Jacket
Outer Jacket Material:
Outer Jacket Material | PVC - Polyvinyl Chloride | |
Overall Cabling
Overall Nominal Diameter: | 0.270 in. |
Pair
Pair Color Code Chart:
Number | Color | 1 | White/Blue & Blue/White | 2 | White/Orange & Orange/White | |
Mechanical Characteristics (Overall)
Operating Temperature Range: | -30°C To +80°C |
UL Temperature Rating: | 80°C (UL AWM Style 2919) |
Bulk Cable Weight: | 37 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 27.500 lbs. |
Min. Bend Radius (Install)/Minor Axis: | 2.750 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: | CM |
CEC/C(UL) Specification: | CM |
AWM Specification: | UL Style 2919 (30 V 80°C) |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test
UL Flame Test: | UL1685 UL Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 24 | |
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 4.6 | |
Max. Operating Voltage - UL:
Voltage | 30 V RMS (UL AWM Style 2919) | 300 V RMS | |
Max. Recommended Current:
Current | 1.8 Amps per conductor @ 25°C | |
Notes (Overall)
Notes: | Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight. |