8104  | | Multi-Conductor - Low Capacitance Computer Cables for EIA RS-232/422 24 AWG stranded (7x32) TC conductors, Datalene® insulation, twisted pairs, overall Beldfoil® (100% coverage) + TC braid shield (65% coverage), 24 AWG stranded TC drain wire, PVC jacket. | For more Information please call 1-800-Belden1 |
| Item # | Putup | Ship Weight | Color | Notes | Item Desc | | 8104 060100 | 100 FT | 5.100 LB | CHROME | | 4 PR #24 FHDPE SH PVC | | 8104 0601000 | 1,000 FT | 46.000 LB | CHROME | C | 4 PR #24 FHDPE SH PVC | | 8104 06010000 | 10,000 FT | 490.000 LB | CHROME | C Y | 4 PR #24 FHDPE SH PVC | | 8104 060500 | 500 FT | 21.000 LB | CHROME | C | 4 PR #24 FHDPE SH PVC | |
| Notes: | |
C = CRATE REEL PUT-UP. Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'. |
Physical Characteristics (Overall)
Conductor
AWG:
| # Pairs | AWG | Stranding | Conductor Material | | 4 | 24 | 7x32 | TC - Tinned Copper | |
Insulation
Insulation Material:
| Insulation Trade Name | Insulation Material | | Datalene® | FPE - Foam Polyethylene | |
Outer Shield
Outer Shield Material:
| Layer # | Outer Shield Trade Name | Type | Outer Shield Material | Coverage (%) | | 1 | Beldfoil® | Tape | Aluminum Foil-Polyester Tape w/Shorting Fold | 100 | | 2 | | Braid | TC - Tinned Copper | 65 | |
Outer Shield Drain Wire AWG:
| AWG | Stranding | Drain Wire Conductor Material | | 24 | 7x32 | TC - Tinned Copper | |
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material | | PVC - Polyvinyl Chloride | |
Overall Cabling
| Overall Nominal Diameter: | 0.302 in. |
Pair
Pair Color Code Chart:
| Number | Color | | 1 | White/Blue & Blue/White | | 2 | White/Orange & Orange/White | | 3 | White/Green & Green/White | | 4 | White/Brown & Brown/White | |
Mechanical Characteristics (Overall)
| Operating Temperature Range: | -30°C To +80°C |
| UL Temperature Rating: | 80°C (UL AWM Style 2919) |
| Bulk Cable Weight: | 47.500 lbs/1000 ft. |
| Max. Recommended Pulling Tension: | 49.500 lbs. |
| Min. Bend Radius (Install)/Minor Axis: | 3 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: | CM |
| CEC/C(UL) Specification: | CM |
| AWM Specification: | UL Style 2919 (30 V 80°C) |
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2002/95/EC (RoHS): | Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
| EU Directive 2002/96/EC (WEEE): | Yes |
| EU Directive 2003/11/EC (BFR): | Yes |
| CA Prop 65 (CJ for Wire & Cable): | Yes |
| MII Order #39 (China RoHS): | Yes |
Flame Test
| UL Flame Test: | UL1685 UL Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 24 | |
Nominal Outer Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 4.1 | |
Max. Operating Voltage - UL:
| Voltage | | 30 V RMS (UL AWM Style 2919) | | 300 V RMS | |
Max. Recommended Current:
| Current | | 1.5 Amps per conductor @ 25°C | |
Notes (Overall)
| Notes: | Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight. |