商品編號: Belden-2412
Belden-2412 CAT-6 23 AWG solid bare copper conductors, polyolefin insulation, film tape separator, PVC jacket with ripcord, sequential footage marking every two feet. CAT 6e 網路線
2412
 |
|
Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cables
23 AWG solid bare copper conductors, polyolefin insulation, film tape separator, PVC jacket with ripcord, sequential footage marking every two feet. |
For more Information
please call
1-800-Belden1 |
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
2412 002A1000 |
1,000 FT |
26.000 LB |
RED |
C |
4PR23 CMR (NONE) |
2412 003A1000 |
1,000 FT |
26.000 FT |
ORANGE |
|
4PR23 CMR (25066515T) |
2412 004A1000 |
1,000 FT |
26.000 FT |
YELLOW |
|
4PR23 CMR (24566715T) |
2412 0041000 |
1,000 FT |
24.000 LB |
YELLOW |
|
4PR23 CMR (24566745T) |
2412 0042500 |
2,500 FT |
60.000 LB |
YELLOW |
|
4PR23 CMR (24566736T) |
2412 005A1000 |
1,000 FT |
26.000 FT |
GREEN, DARK |
|
4PR23 CMR (25066815T) |
2412 0051000 |
1,000 FT |
24.000 LB |
GREEN, DARK |
|
4PR23 CMR (25066885T) |
2412 006A1000 |
1,000 FT |
26.000 FT |
BLUE, LIGHT |
|
4PR23 CMR (24566915T) |
2412 0061000 |
1,000 FT |
24.000 LB |
BLUE, LIGHT |
|
4PR23 CMR (24566945T) |
2412 0061400 |
1,400 FT |
0.000 |
BLUE, LIGHT |
|
4PR23 CMR (24566931T) |
2412 0062500 |
2,500 FT |
60.000 LB |
BLUE, LIGHT |
|
4PR23 CMR (24566936T) |
2412 007A1000 |
1,000 FT |
26.000 FT |
VIOLET |
|
4PR23 CMR (24566P15T) |
2412 0081000 |
1,000 FT |
24.000 LB |
GRAY |
|
4PR23 CMR (24566185T) |
2412 009A1000 |
1,000 FT |
26.000 FT |
WHITE |
|
4PR23 CMR (24566315T) |
2412 0091000 |
1,000 FT |
24.000 LB |
WHITE |
|
4PR23 CMR (24566345T) |
2412 0092500 |
2,500 FT |
60.000 LB |
WHITE |
|
4PR23 CMR (24566336T) |
2412 010A1000 |
1,000 FT |
26.000 FT |
BLACK |
|
4PR23 CMR (24566415T) |
2412 0101000 |
1,000 FT |
24.000 LB |
BLACK |
|
4PR23 CMR (24566485T) |
|
Notes: |
|
C = CRATE REEL PUT-UP.
|
Usage (Overall)
Suitable Applications: |
Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs |
AWG |
Stranding |
Conductor Material |
4 |
23 |
Solid |
BC - Bare Copper |
|
Insulation
Insulation Material:
Insulation Material |
PO - Polyolefin |
|
Outer Shield
Outer Shield Material:
Outer Shield Material |
Unshielded |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
PVC - Polyvinyl Chloride |
|
Outer Jacket Ripcord: |
Yes |
Overall Cabling
Overall Cabling Fillers: |
Center Tape |
Overall Nominal Diameter: |
0.220 in. |
Pair
Pair Color Code Chart:
Number |
Color |
1 |
White/Blue Stripe and Blue |
2 |
White/Orange Stripe and Orange |
3 |
White/Green Stripe and Green |
4 |
White/Brown Stripe and Brown |
|
Mechanical Characteristics (Overall)
Storage Temperature Range: |
-20°C To +75°C |
Installation Temperature Range: |
+5°C To +50°C |
Operating Temperature Range: |
-20°C To +75°C |
Bulk Cable Weight: |
24 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
40 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
1 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
CEC/C(UL) Specification: |
CMR |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Telecommunications Standards: |
568-B.2-1 Category 6 |
Other Specification: |
Third party verified to Category 6 |
Flame Test
UL Flame Test: |
UL1666 Riser |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Mutual Capacitance:
Capacitance (pF/ft) |
17.000 |
|
Maximum Capacitance Unbalance (pF/100 m): |
330 |
Nominal Velocity of Propagation:
Maximum Delay:
Delay (ns/100 m) |
537 @ 100MHz |
|
Max. Delay Skew:
Maximum Conductor DC Resistance:
DCR @ 20°C (Ohm/100 m) |
8.2 |
|
Max. Operating Voltage - UL:
Maximum DCR Unbalanced:
DCR Unbalance @ 20°C (%) |
5 |
|
Electrical Characteristics-Premise (Overall)
Premise Cable Electrical Table 1:
Freq. (MHz) |
Max. Attenuation (dB/100 m) |
Min. NEXT (dB) |
Min. PSNEXT (dB) |
Min. ACR (dB) |
Min. PSACR (dB) |
Min RL (dB) |
0.772 |
1.800 |
77.0 |
75.0 |
75.2 |
73.2 |
|
1 |
2.000 |
75.3 |
73.3 |
73.3 |
71.3 |
20.000 |
4 |
3.700 |
66.3 |
64.3 |
62.6 |
60.6 |
23.000 |
8 |
5.200 |
63.3 |
61.3 |
58.1 |
56.1 |
24.500 |
10 |
5.800 |
61.8 |
59.8 |
56.0 |
54.0 |
25.000 |
16 |
7.400 |
58.6 |
56.6 |
51.2 |
49.2 |
25.000 |
20 |
8.300 |
57.1 |
55.1 |
48.8 |
46.8 |
25.000 |
25 |
9.300 |
55.5 |
53.5 |
46.3 |
44.3 |
24.300 |
31.25 |
10.400 |
54.0 |
52.0 |
43.6 |
41.6 |
23.600 |
62.5 |
15.000 |
49.1 |
47.1 |
34.1 |
32.1 |
21.500 |
100 |
19.300 |
45.8 |
43.8 |
26.5 |
24.5 |
20.800 |
155 |
24.500 |
42.7 |
40.7 |
18.2 |
16.2 |
19.500 |
200 |
28.300 |
40.9 |
38.9 |
12.6 |
10.6 |
18.700 |
250 |
32.100 |
39.3 |
37.3 |
7.2 |
5.2 |
18.000 |
300 |
35.600 |
38.1 |
36.1 |
2.5 |
-0.5 |
17.500 |
350 |
38.900 |
37.1 |
35.1 |
-1.7 |
-3.7 |
17.000 |
400 |
42.000 |
36.3 |
34.3 |
-5.7 |
-7.7 |
16.600 |
450 |
45.000 |
35.5 |
33.5 |
-9.5 |
-11.5 |
16.200 |
500 |
47.900 |
34.8 |
32.8 |
-13.0 |
-15.0 |
15.900 |
550 |
50.600 |
34.2 |
32.2 |
-16.4 |
-18.4 |
15.600 |
|
Premise Cable Electrical Table 2:
Freq. (MHz) |
Input (Unfitted) Imp. (Ohms) |
Fitted Impedance |
Min. ELFEXT (dB) |
Min. PSELFEXT (dB) |
0.772 |
|
102 ± 15 |
73.0 |
70.0 |
1 |
100 ± 15 |
102 ± 15 |
70.8 |
67.8 |
4 |
100 ± 15 |
100 ± 15 |
58.8 |
55.8 |
8 |
100 ± 15 |
100 ± 15 |
52.7 |
49.7 |
10 |
100 ± 15 |
100 ± 15 |
50.8 |
47.8 |
16 |
100 ± 15 |
100 ± 15 |
46.7 |
43.7 |
20 |
100 ± 15 |
100 ± 15 |
44.8 |
41.8 |
25 |
100 ± 15 |
100 ± 15 |
42.8 |
39.8 |
31.25 |
100 ± 15 |
100 ± 15 |
40.9 |
37.9 |
62.5 |
100 ± 15 |
100 ± 15 |
34.9 |
31.9 |
100 |
100 ± 15 |
100 ± 15 |
30.8 |
27.8 |
155 |
100 ± 22 |
100 ± 15 |
27.0 |
24.0 |
200 |
100 ± 22 |
100 ± 15 |
24.8 |
21.8 |
250 |
100 ± 32 |
100 ± 15 |
22.8 |
19.8 |
300 |
100 ± 32 |
100 ± 15 |
21.3 |
18.3 |
350 |
|
|
19.9 |
16.9 |
400 |
|
|
18.8 |
15.8 |
450 |
|
|
17.7 |
14.7 |
500 |
|
|
16.8 |
13.8 |
550 |
|
|
16.0 |
13.0 |
|
Notes (Overall)
Notes: |
Jacket sequentially marked at 2 ft./1m intervals. Third party verified to TIA/EIA-568-B.2-1, Category 6. Values above 300 MHz are for Engineering Informaton Only. US Patents 5424491, 6570095, 6998537. |
Reference (Overall)
Previous Part Number: |
24566415, 25066515T, 24566745, 24566745T, 24566745T+HU, 24566736T, 24566715, 24566715T, 25066885, 25066885T, 25066815T, 24566945, 24566945T, 24566945T+HU, 24566931, 24566931T, 24566931T+HU, 24566936T, 24566915, 24566915T, 24566915T+HU, 24566015, 24566015T, 24566P15, 24566P15T, 24566185, 24566185T, 24566185T+HU, 24566115T, 24566345, 24566345T, 24566345T+HU, 24566336T, 24566315, 24566315T, 24566315T+HU, 24566485, 24566485T, 24566415T, 24566415T |
|