| 商品編號: Belden-3082K
Belden-3082K CL2 (Flat) 扁平型電纜 DeviceBus® for ODVA DeviceNet™
Flat - DeviceBus® for ODVA DeviceNet™ 16 AWG stranded (19x29) tinned copper conductors, PVC insulation (Power), FPE insulation (Data), unshielded, sunlight-resistant PVC jacket. |
| |
| | |
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
| |
| | |
| | 082K  | | Flat - DeviceBus® for ODVA DeviceNet™ 16 AWG stranded (19x29) tinned copper conductors, PVC insulation (Power), FPE insulation (Data), unshielded, sunlight-resistant PVC jacket. | For more Information please call 1-800-Belden1 | Item # | Putup | Ship Weight | Color | Notes | Item Desc | | Physical Characteristics (Overall) Conductor AWG: # Conductors | AWG | Stranding | Conductor Material | 4 | 16 | 19x29 | TC - Tinned Copper | | Insulation Insulation Material: Insulation Material | Dia. (in.) | PVC - Polyvinyl Chloride (Power Pairs) | 0.110 | FPE - Foam Polyethylene (Data Pairs) | 0.110 | | Outer Shield Outer Shield Material: Outer Shield Material | Unshielded | | Outer Jacket Outer Jacket Material: Outer Jacket Material | PVC - Polyvinyl Chloride | | Overall Cabling Overall Nominal Diameter: | 0.760 x 0.210 in. | Pair Pair Color Code Chart: Number | Color | Power Pair | Red & Black | Data Pair | Blue & White | | Mechanical Characteristics (Overall) Operating Temperature Range: | -25°C To +75°C | UL Temperature Rating: | 75°C | Max. Recommended Pulling Tension: | 160 lbs. | Min. Bend Radius (Install)/Minor Axis: | 2.100 in. | Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: | CMG, CL2, PLTC | CEC/C(UL) Specification: | CMG | EU Directive 2000/53/EC (ELV): | Yes | EU Directive 2002/95/EC (RoHS): | Yes | EU RoHS Compliance Date (mm/dd/yyyy): | 04/01/2005 | EU Directive 2002/96/EC (WEEE): | Yes | EU Directive 2003/11/EC (BFR): | Yes | CA Prop 65 (CJ for Wire & Cable): | Yes | MII Order #39 (China RoHS): | Yes | Other Specification: | Product is fully compliant with the ODVA specification, and is compatible with the approved Allen Bradley KwikLink(TM) connectors. | Flame Test Suitability Plenum/Non-Plenum Electrical Characteristics (Overall) Nom. Characteristic Impedance: Description | Impedance (Ohm) | Data Pair | 120 | | Nom. Capacitance Conductor to Conductor: Description | Capacitance (pF/ft) | Data Pair | 14.7 | | Nominal Velocity of Propagation: Nominal Delay: Description | Freq. (MHz) | Delay (ns/ft) | Data Pair | | 1.6 | | Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/1000 ft) | 4.9 | | Max. Attenuation: Description | Freq. (MHz) | Attenuation (dB/100 ft.) | Data Pair | .125 | .13 | Data Pair | .500 | .25 | Data Pair | 1.000 | .40 | | Max. Operating Voltage - UL: Max. Recommended Current: Current | 4 Amps per conductor @ 24 V per NEC CL2 (Power Pair) | | Notes (Overall) Notes: | ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark. KwikLink(TM) is a trademark of Rockwell Automation, Inc. | |
| |
|
|