| | 商品編號: Belden-3082KP
Belden-3082KP Flat 扁平型電纜 - DeviceBus® for ODVA DeviceNet™ 16 AWG stranded
Flat - DeviceBus® for ODVA DeviceNet™ 16 AWG stranded (19x29) tinned copper conductors, PVC insulation, unshielded, sunlight-resistant PVC jacket. |
| |
| | |
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
| |
| | |
| | 3082KP  | | Flat - DeviceBus® for ODVA DeviceNet™ 16 AWG stranded (19x29) tinned copper conductors, PVC insulation, unshielded, sunlight-resistant PVC jacket. | For more Information please call 1-800-Belden1 | | Item # | Putup | Ship Weight | Color | Notes | Item Desc | | Physical Characteristics (Overall) Conductor AWG: | # Conductors | AWG | Stranding | Conductor Material | Dia. (in.) | | 4 | 16 | 19x29 | TC - Tinned Copper | .110 | | Insulation Insulation Material: | Insulation Material | Dia. (in.) | | PVC - Polyvinyl Chloride | .110 | | Outer Shield Outer Shield Material: | Outer Shield Material | | Unshielded | | Outer Jacket Outer Jacket Material: | Outer Jacket Material | | PVC - Polyvinyl Chloride | | Overall Cabling | Overall Nominal Diameter: | 0.760 x 0.210 in. | Pair Pair Color Code Chart: | Number | Color | | 1 | Red/Black | | 2 | Blue/White | | Mechanical Characteristics (Overall) | Operating Temperature Range: | -25°C To +75°C | | UL Temperature Rating: | 75°C | | Max. Recommended Pulling Tension: | 110 lbs. | | Min. Bend Radius (Install)/Minor Axis: | 2.100 in. | Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs | NEC/(UL) Specification: | CMG, ITC, PLTC, TC | | CEC/C(UL) Specification: | CMG | | EU Directive 2000/53/EC (ELV): | Yes | | EU Directive 2002/95/EC (RoHS): | Yes | | EU RoHS Compliance Date (mm/dd/yyyy): | 04/01/2005 | | EU Directive 2002/96/EC (WEEE): | Yes | | EU Directive 2003/11/EC (BFR): | Yes | | CA Prop 65 (CJ for Wire & Cable): | Yes | | MII Order #39 (China RoHS): | Yes | | Other Specification: | Product is fully compliant with the ODVA specification, and is compatible with the approved Allen Bradley KwikLink(TM) connectors. | Flame Test | UL Flame Test: | UL1685 FT4 Loading | Suitability Plenum/Non-Plenum Electrical Characteristics (Overall) Maximum Conductor DC Resistance: | DCR @ 20°C (Ohm/100 m) | | 4.9 ohms/1000 ft | | Max. Operating Voltage - UL: | Voltage | Description | | 300 V RMS | PLTC, ITC, CMG | | 600 V RMS | TC | | Max. Recommended Current: | Current | | 8 Amps per conductor @ 25°C | | Notes (Overall) | Notes: | Class 1 Power. ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark. KwikLink(TM) is a trademark of Rockwell Automation, Inc. | |
| |
|
|