| 商品編號: Belden-88444
Belden-88444 22 AWG x 4C, FEP - FEP jacket. Plenum 4芯鐵氟龍CMP級声音音響, 通訊, 儀表控制電纜
Unshielded Audio, Control and Instrumentation Cables Plenum-Rated and Non-Plenum 22 AWG Stranded (7x30) Tinned Copper Conductors • Conductors Cabled (continued) PVC Insulation • Chrome PVC Jacket UL AWM Style 2576 Belden-8457 NEC: 12C (150V 80°C) CMG Chart 1 CMG FT4 Section Belden-8458 NEC: 15C CMG Chart 2R CMG FT4 Section Belden-9431 NEC: 20C CMG Chart 2R CMG FT4 Section Belden-8459 NEC: 25C CMG Chart 2R CMG FT4 Section Belden-9432 NEC: 30C CMG Chart 2R CMG FT4 Section Belden-9433 NEC: 40C CMG Chart 2R CMG FT4 Section Belden-9434 NEC: 50C CMG Chart 2R CMG FT4 Section Plenum • FEP Insulation • Red FEP Jacket 300V RMS, Non-conduit Belden-88442* NEC: 2C CMP FT6 300V RMS, Non-conduit Belden-88444 NEC: 4C CMP FT6 Suitable for Outdoor and Direct Burial applications. Plenum • FEP Insulation • Natural Flamarrest® Jacket 300V RMS, Non-conduit Belden-82442* NEC: 2C CMP FT6 300V RMS, Non-conduit Belden-82444 NEC: 4C CMP FT6 Green |
| |
| | |
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
| |
| | |
| | 88444
 | | Multi-Conductor - Audio, Control and Instrumentation Cable 22 AWG stranded (7x30) TC conductors, conductors cabled, FEP insulation, FEP jacket. | For more Information please call
1-800-Belden1 |
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 88444 002100 | 100 FT | 2.900 LB | RED | C | 4#22 FEP FEP | 88444 0021000 | 1,000 FT | 15.000 LB | RED | C | 4#22 FEP FEP | 88444 002500 | 500 FT | 9.000 LB | RED | C | 4#22 FEP FEP |
|
Notes: | | C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall) Conductor AWG: # Conductors | AWG | Stranding | Conductor Material | 4 | 22 | 7x30 | TC - Tinned Copper |
|
Insulation Insulation Material: Insulation Material | Wall Thickness (in.) | FEP - Fluorinated Ethylene Propylene | .006 |
|
Outer Shield Outer Shield Material: Outer Shield Material | Unshielded |
|
Outer Jacket Outer Jacket Material: Outer Jacket Material | Nom. Wall Thickness (in.) | FEP - Fluorinated Ethylene Propylene | .010 |
|
Overall Cabling Overall Cabling Color Code Chart: Number | Color | 1 | Black | 2 | White | 3 | Red | 4 | Green |
|
Overall Nominal Diameter: | 0.121 in. |
Mechanical Characteristics (Overall) Operating Temperature Range: | -70°C To +200°C |
Bulk Cable Weight: | 14.600 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 36 lbs. |
Min. Bend Radius (Install)/Minor Axis: | 1.500 in. |
Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: | CMP |
CEC/C(UL) Specification: | CMP |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 04/01/2005 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test Suitability Suitability - Outdoor: | Yes |
Plenum/Non-Plenum Electrical Characteristics (Overall) Nom. Inductance: Nom. Capacitance Conductor to Conductor: Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/1000 ft) | 15 |
|
Nominal Conductor Loop Resistance: Resistance @ 20°C (Ohm/1000 ft) | 30 |
|
Max. Operating Voltage - UL: Max. Recommended Current: Current | 3.3 Amps per conductor @ 25°C (10°C rise in temp) |
|
|
| | | |
| | Introduction Belden® multi-conductor cables are manufactured in a wide variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions. These cables meet the technical requirements of many different types of systems. In fact, Belden offers one of the broadest lines of UL Listed, NEC and CEC multi-conductor cables available from any single source. Applications for multi-conductor cables include computers, communications, instrumentation, sound, control, audio, and data transmission. Each of these cables is designed to protect signal integrity under critical conditions by reducing hum, noise, and crosstalk. To assist you in selecting the proper cable for your application, both the suggested working voltages and the maximum temperature ratings are indicated for each applicable product in this section. Most of our multi-conductor cables are available from stock. Many of these are available off the shelf from distributors. If you have a new or unusual application or you cannot find a multi-conductor cable in this catalog section that meets your technical requirements, contact Technical Support at 1-800-BELDEN-1. Multi-Conductor Cables Packaging Belden’s unique UnReel® cable dispenser is available for many of the multi-conductor products listed in this section. The letter “U” before the specified put-up length denotes UnReel packaging |
| |
|
|