BELDEN-9934
Belden9934 Awg24-9C Low-Capacitance Computer Cable for EIA RS-232/423 低電容雙屏蔽隔離電腦傳輸電纜線
9934
|
|
Multi-Conductor - Low-Capacitance Computer Cable for EIA RS-232/423
24 AWG stranded (7x32) TC conductors, Datalene® insulation, overall Beldfoil® (100% coverage) + TC braid shield (65% coverage), drain wire, PVC jacket. |
For more Information
Please call
1-800-Belden1 |
Click here for Certificate
Item ## |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
9934 060100 |
100 FT |
5.200 LB |
CHROME |
|
9 #24 FHDPE SH PVC |
9934 0601000 |
1,000 FT |
48.000 LB |
CHROME |
C |
9 #24 FHDPE SH PVC |
9934 060500 |
500 FT |
24.000 LB |
CHROME |
C |
9 #24 FHDPE SH PVC |
9934 0605000 |
5,000 FT |
245.000 LB |
CHROME |
C |
9 #24 FHDPE SH PVC |
|
Notes: |
|
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors |
AWG |
Stranding |
Conductor Material |
9 |
24 |
7x32 |
TC - Tinned Copper |
|
Total Number of Conductors: |
9 |
Insulation
Insulation Material:
Insulation Trade Name |
Insulation Material |
Wall Thickness (in.) |
Datalene® |
FPE - Foam Polyethylene |
0.015 |
|
Outer Shield
Outer Shield Material:
Layer # |
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
1 |
Beldfoil® |
Tape |
Aluminum Foil-Polyester Tape |
100 |
2 |
|
Braid |
TC - Tinned Copper |
65 |
|
Outer Shield Drain Wire AWG:
AWG |
Stranding |
Drain Wire Conductor Material |
24 |
Stranded |
TC - Tinned Copper |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
Nom. Wall Thickness (in.) |
PVC - Polyvinyl Chloride |
0.035 |
|
Overall Cable
Overall Cabling Color Code Chart:
Number |
Color |
1 |
Black |
2 |
White |
3 |
Red |
4 |
Green |
5 |
Brown |
6 |
Blue |
7 |
Orange |
8 |
Yellow |
9 |
Purple |
|
Overall Nominal Diameter: |
0.300 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-30°C To +80°C |
UL Temperature Rating: |
80°C (UL AWM Style 2919) |
Bulk Cable Weight: |
44 lbs/1000 ft. |
Min. Bend Radius/Minor Axis: |
3 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CM |
CEC/C(UL) Specification: |
CM |
AWM Specification: |
UL Style 2919 (30 V 80°C) |
EU Directive 2011/65/EU (ROHS II): |
Yes |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
UL Flame Test: |
UL1685 UL Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
24 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
3.85 |
|
Max. Operating Voltage - UL:
Voltage |
Description |
30 V RMS |
UL AWM Style 2919 |
300 V RMS |
CM |
|
Max. Recommended Current:
Current |
1.5 Amps per conductor @ 25°C |
|
Notes (Overall)
Notes: |
Datalene® insulation features include a low dielectric constant and a low dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight. |
|
|