| 商品編號: Belden-9952
Belden-9952 MIL-W-16878 (Type B) 16 AWG x 2C TC, TC braid shield 600V 105°C PVC/Nylon -PVC jacket. 白色軍規PVC尼龍絕緣PVC被覆鍍錫銅網隔離電纜
Overall Braid Shield MIL-W-16878 (Type B) Conductors, Shielded and Jacketed† Communication and Instrumentation Cables 22 AWG Stranded (19x34) TC Conductors • .003″ (.76mm) Clear Nylon Skin over Insulation • Tinned Copper Braid Shield (90% Coverage) PVC Insulation • White PVC Jacket 600V RMS 105°CBelden-9965 — 1C VW-1 Belden-9966 — 2C Belden-9967 — 3C†† Belden-9968 — 4C†† 20 AWG Stranded (19x32) Tinned Copper Conductors • .004″ (.10mm) Clear Nylon Skin over Insulation • TC Braid Shield (90% Coverage) PVC Insulation • White PVC Jacket 600V RMS 105°CBelden-9961 — 1C Belden-9962 — 2C†† Belden-9963 — 3C†† Belden-9964 — 4C†† 16 AWG Stranded (19x29) Tinned Copper Conductors • .004″ (.10mm) Clear Nylon Skin over Insulation • TC Braid Shield (90% Coverage) PVC Insulation • White PVC Jacket 600V RMS 105°CBelden-9951 — 1C VW-1 Belden-9952 — 2C†† Belden-9953 — 3C†† Belden-9954 — 4C†† |
| |
| | |
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
| |
| | |
| | 9952
 | | Multi-Conductor - 2 Conductors Cabled-Communication and Instrumentation Cable 16 AWG stranded (19x29) tinned copper conductors, conductors cabled, nylon skin over insulation, PVC insulation, tinned copper braid shield (90% coverage), PVC jacket. | For more Information please call
1-800-Belden1 |
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 9952 009100 | 100 FT | 4.600 LB | WHITE | | 2 #16 PVC/NY SHLD PVC | 9952 0091000 | 1,000 FT | 42.000 LB | WHITE | C | 2 #16 PVC/NY SHLD PVC | 9952 009500 | 500 FT | 19.000 LB | WHITE | | 2 #16 PVC/NY SHLD PVC |
|
Notes: | | C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall) Conductor AWG: # Conductors | AWG | Stranding | Conductor Material | 2 | 16 | 19x29 | TC - Tinned Copper |
|
Insulation Insulation Material: Layer # | Insulation Material | Wall Thickness (in.) | 1 | PVC - Polyvinyl Chloride | .012 | 2 | Nylon | .004 |
|
Insulation Resistance: | 500 megohms/1000 ft. @ 500 VDC |
Outer Shield Outer Shield Material: Type | Outer Shield Material | Coverage (%) | Braid | TC - Tinned Copper | 90 |
|
Outer Jacket Outer Jacket Material: Outer Jacket Material | Nom. Wall Thickness (in.) | PVC - Polyvinyl Chloride | .025 |
|
Overall Cabling Overall Cabling Lay Length & Direction: Length (in.) | Twists (ft.) | 2.125 | 5.6 |
|
Overall Cabling Color Code Chart: Overall Nominal Diameter: | 0.250 in. |
Mechanical Characteristics (Overall) Operating Temperature Range: | -20°C To +105°C |
UL Temperature Rating: | 105°C |
Bulk Cable Weight: | 38.200 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 60.800 lbs. |
Min. Bend Radius (Install)/Minor Axis: | 2.500 in. |
Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 10/01/2005 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Military Specification: | MIL-W-16878E/17 (insulated conductor) |
Flame Test UL Flame Test: | UL1685 UL Loading, VW-1 |
Plenum/Non-Plenum Electrical Characteristics (Overall) Nom. Inductance: Nom. Capacitance Conductor to Conductor: Nom. Capacitance Cond. to Other Conductor & Shield: Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/1000 ft) | 4.3 |
|
Nominal Outer Shield DC Resistance: DCR @ 20°C (Ohm/1000 ft) | 5.7 |
|
Max. Operating Voltage - UL: Max. Recommended Current: Current | 6.5 Amps per conductor @ 25°C |
|
|
| | | |
| | Introduction Belden® multi-conductor cables are manufactured in a wide variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions. These cables meet the technical requirements of many different types of systems. In fact, Belden offers one of the broadest lines of UL Listed, NEC and CEC multi-conductor cables available from any single source. Applications for multi-conductor cables include computers, communications, instrumentation, sound, control, audio, and data transmission. Each of these cables is designed to protect signal integrity under critical conditions by reducing hum, noise, and crosstalk. To assist you in selecting the proper cable for your application, both the suggested working voltages and the maximum temperature ratings are indicated for each applicable product in this section. Most of our multi-conductor cables are available from stock. Many of these are available off the shelf from distributors. If you have a new or unusual application or you cannot find a multi-conductor cable in this catalog section that meets your technical requirements, contact Technical Support at 1-800-BELDEN-1. Multi-Conductor Cables Packaging Belden’s unique UnReel® cable dispenser is available for many of the multi-conductor products listed in this section. The letter “U” before the specified put-up length denotes UnReel packaging |
| |
|
|