89248
|
|
Coax - 75 Ohm Coax
18 AWG solid .040" bare copper conductor, plenum, foam FEP insulation, Duofoil® + tinned copper braid shield (65% coverage), FEP jacket. |
For more Information
please call
1-800-Belden1 |
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
89248 0101000 |
1,000 FT |
33.000 LB |
BLACK |
C |
#18 FFEP RG 6/U COAX |
89248 0102000 |
2,000 FT |
64.000 LB |
BLACK |
C |
#18 FFEP RG 6/U COAX |
89248 010500 |
500 FT |
15.000 LB |
BLACK |
C |
#18 FFEP RG 6/U COAX |
|
Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical Characteristics (Overall)
Conductor
AWG:
# Coax |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
1 |
18 |
Solid |
BC - Bare Copper |
.040 |
|
Insulation
Insulation Material:
Insulation Material |
Dia. (in.) |
FFEP - Foam Fluorinated Ethylene Propylene |
.170 |
|
Outer Shield
Outer Shield Material:
Layer # |
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
1 |
Duofoil® |
Tape |
Aluminum Foil-Polyester Tape-Aluminum Foil |
100 |
2 |
|
Braid |
TC - Tinned Copper |
65 |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
FEP - Fluorinated Ethylene Propylene |
|
Overall Cabling
Overall Nominal Diameter: |
0.222 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-70°C To +200°C |
Non-UL Temperature Rating: |
200°C |
Bulk Cable Weight: |
30 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
45 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
3 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CMP |
CEC/C(UL) Specification: |
CMP |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
04/01/2005 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
Suitability
Suitability - Indoor: |
Yes |
Suitability - Outdoor: |
Yes |
Suitability - Aerial: |
Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
6.4 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
5.1 |
|
Nom. Attenuation:
Freq. (MHz) |
Attenuation (dB/100 ft.) |
1 |
.3 |
10 |
.7 |
50 |
1.5 |
100 |
2.1 |
200 |
3.1 |
400 |
4.5 |
700 |
6.0 |
900 |
6.9 |
1000 |
7.3 |
|
Max. Operating Voltage - UL:
Minimum Return Loss:
Description |
Freq. (MHz) |
Start Freq. (MHz) |
Stop Freq. (MHz) |
Min. RL (dB) |
|
|
5 |
450 |
23 |
|
Notes (Overall)
Notes: |
100% Sweep tested 5 MHz to 450 MHz. |