BELDEN-1313A
Belden 1313A 10Awgx2C Outdoor (Direct Burial) Speaker Cable stranded (259x34) oxygen-free high-conductivity bare copper conductors 可直接埋設屋(內)外(無氧銅)廣播擴音電纜線
1313A
 |
|
Multi-Conductor - Speaker Cable
10 AWG stranded (259x34) oxygen-free high-conductivity bare copper conductors, PO insulation, conductors cabled, PVC jacket. Sequential footage marking every two feet. |
For more Information
Please call
1-800-Belden1 |

Click here for Certificate
Item ## |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
1313A 0081000 |
1,000 FT |
109.000 LB |
GRAY |
C |
2 #10 PE FRPVC |
1313A 008500 |
500 FT |
55.000 LB |
GRAY |
C |
2 #10 PE FRPVC |
1313A 0101000 |
1,000 FT |
109.000 LB |
BLACK |
C |
2 #10 PE FRPVC |
1313A 010500 |
500 FT |
55.000 LB |
BLACK |
C |
2 #10 PE FRPVC |
1313A 1SL1000 |
1,000 FT |
109.000 LB |
WHITE 1SL |
C |
2 #10 PE FRPVC |
1313A 1SL500 |
500 FT |
55.000 LB |
WHITE 1SL |
C |
2 #10 PE FRPVC |
|
Notes: |
|
C = CRATE REEL PUT-UP. |
Usage (Overall)
Suitable Applications: |
Speaker Cable, Direct Burial, Indoor/Outdoor Home Theater, In-Wall Speaker, Outdoor Speaker |
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
2 |
10 |
259x34 |
High Conductivity BC - Bare Copper |
.132 |
|
Total Number of Conductors: |
2 |
Insulation
Insulation Material:
Insulation Material |
Dia. (in.) |
PO - Polyolefin |
.170 |
|
Outer Shield
Outer Shield Material:
Outer Shield Material |
Unshielded |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
PVC - Polyvinyl Chloride |
|
Overall Cable
Overall Cabling Color Code Chart:
Number |
Color |
1 |
Black |
2 |
Red |
|
Overall Nominal Diameter: |
0.428 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-20°C To +75°C |
UL Temperature Rating: |
75°C |
Bulk Cable Weight: |
100 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
275 lbs. |
Min. Bend Radius/Minor Axis: |
4.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CL3, CM |
CEC/C(UL) Specification: |
CM |
EU Directive 2011/65/EU (ROHS II): |
Yes |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
01/11/2005 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Other Specification: |
Sunlight resistant in Black and White. |
Flame Test
UL Flame Test: |
UL1581 Vertical Flame and FT-1 Flame Test |
Suitability
Suitability - Indoor: |
Yes |
Suitability - Outdoor: |
Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nominal Velocity of Propagation:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
1.0 |
|
Max. Operating Voltage - UL:
Max. Recommended Current:
Current |
17 Amps per conductor @ 25°C |
|
|