    Belden 7721A  (RG59+2Pair)  Composite  -  Broadband Coax Headend/Video Cable 寬頻影像(有線電視)頭端用複合式同軸電纜
    看原圖
    162671

    商品編號: Belden-7721A

    Belden 7721A  (RG59+2Pair)  Composite  -  Broadband Coax Headend/Video Cable 寬頻影像(有線電視)頭端用複合式同軸電纜
     
    DESCRIPTION:
    Coax-20 AWG,solid silver-plated conductor,gas injected foam polyethylene insulation Dubond® plus tinned copper braid shield;pairs-2,22 AWG stranded tinned copper conductors,twisted pairs,individually Beldfoil® shielded,polyolefin insulation,PVC jacket. 
    PHYSICAL CHARACTERISTICS :  
       
    COAX :
     
    COAX CONDUCTOR :
    Number of Coax: 1
     
    Series Type (Single Coax): Series 59
     
    COAX CONDUCTOR :
    Coax AWG: 20
    Coax Stranding: Solid
    Coax Conductor Diameter: .032 in.
    Coax Conductor Material: SPC - Silver Plated Copper
     
    COAX INSULATION :
    Coax Insulation Material: Gas-injected FHDPE - Foam High Density Polyethylene
    Coax Insulation Diameter: .145 in.
     
    COAX INNER SHIELD :
    Coax Shield Material Trade Name: Duobond® II
    Coax Shield Type: Tape/Braid
    Coax Shield Material:
    Layer Number  Trade Name  Type  Material  Coverage (%) 
     1  Bonded Duobond®  Tape  Bonded Aluminum Foil-Polyester Tape-Aluminum Foil  100
     2    Braid  TC - Tinned Copper  95
     
       
    TWISTED PAIR CABLE(S) :
     
    TWISTED PAIR CABLE CONDUCTOR :
    Number of Pairs: 2
    Twisted Pair AWG: 22
    Twisted Pair Stranding: 7x30
    Twisted Pair Conductor Diameter: .030 in.
    Twisted Pair Conductor Material: TC - Tinned Copper
     
    TWISTED PAIR CABLE INSULATION :
    Twisted Pair Insulation Material: PO - Polyolefin
    Twisted Pair Nom. Insulation Wall Thickness: .008 in.
     
    TWISTED PAIR OVERALL DIAMETER :
    Twisted Pair Overall Nominal Diameter: .138
       
    PAIR :
     
    Pair Lay Length & Direction:
    Lay Length (in.)  Direction  Twists/ft (twist/ft) 
     1.75    6.86
     
    Pair Inner Shield Material:
    Description  Layer  Trade Name  Type  Material  Coverage (%) 
     Each Pair  1  Beldfoil®  Tape    100
     
    Pair Inner Shield Drain Wire AWG: 22
    Pair Inner Shield Drain Wire Stranding: 7x30
    Pair Inner Shield Drain Wire Conductor Material: TC - Tinned Copper
    Pair Color Code Chart:
    Number  Color 
     1  Black & Red
     2  Green & White
     
       
    MULTICONDUCTOR CABLE(S) :
     
    CONDUCTOR :
    Total Number of Conductors: 5
    Multi-Conductor Conductor Diameter: .046 in.
       
    OUTER JACKET :
     
    Outer Jacket Material: PVC - Polyvinyl Chloride
       
    OVERALL CABLING :
    Overall Nominal Diameter: .235 x .511 in.
    MECHANICAL CHARACTERISTICS :  
    Operating Temperature Range: 0°C To +80°C
    Other Temperature Range: 80°C
    Bulk Cable Weight: 57 lbs/1000 ft.
    Max. Recommended Pulling Tension: 125 lbs.
    Min. Bend Radius (Install): 2.5 in.
    APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :  
       
    APPLICABLE STANDARDS :
    NEC/(UL) Specification: CM, CATV
    CEC/C(UL) Specification: CM
       
    FLAME TEST :
    UL Flame Test: UL1581 Vertical Tray
    ELECTRICAL CHARACTERISTICS :  
       
    COAX :
    Coax Nom. Characteristic Impedance: 75 +/- 3 Ω
    Coax Nom. Inductance: 0.107 µH/ft
    Coax Nom. Capacitance Conductor to Shield: 16.2 pF/ft
    Coax Nominal Velocity of Propagation: 83 %
    Coax Nominal Delay: 1.22 ns/ft
    Coax Nom. Conductor DC Resistance @ 20 Deg. C: 10.1 Ω/1000 ft
    Coax Nominal Shield DC Resistance: 3.5 Ω/1000 ft
    Coax Minimum Structural Return Loss:
    Description  Frequency (MHz)  Start Frequency (MHz)  Stop Frequency (MHz)  Minimum Structural Return Loss (dB) 
         5  1000  20
     
    Coax Nom. Attenuation:
    Description  Frequency (MHz)  Start Frequency (MHz)  Stop Frequency (MHz)  Nom. Attenuation (dB/100 ft.) 
       1      0.29
       3.58      0.55
       5      0.65
       10      0.87
       55      1.83
       211      3.61
       270      4.10
       300      4.33
       330      4.69
       400      5.02
       450      5.33
       550