9275
 |
|
Coax - 75 Ohm Coax
Series 59, 20 AWG solid .032" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duofoil® or Duobond® + aluminum braid shield (40% coverage), PVC jacket. |
For more Information
Please call
1-800-Belden1 |

Click here for Certificate
| Item ## |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
| 9275 009U1000 |
1,000 FT |
23.000 LB |
WHITE |
|
#20 LDPE/GIFHDLDPE SH FRPVC |
| 9275 010U1000 |
1,000 FT |
23.000 LB |
BLACK |
|
#20 LDPE/GIFHDLDPE SH FRPVC |
| 9275 010U500 |
500 FT |
12.000 LB |
BLACK |
|
#20 LDPE/GIFHDLDPE SH FRPVC |
| 9275 0101000 |
1,000 FT |
24.000 LB |
BLACK |
|
#20 LDPE/GIFHDLDPE SH FRPVC |
|
Physical Characteristics (Overall)
Conductor
AWG:
| # Coax |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
| 1 |
20 |
Solid |
BCCS - Bare Copper Covered Steel |
.032 |
|
| Total Number of Conductors: |
1 |
Insulation
Insulation Material:
| Insulation Material |
Dia. (in.) |
| Gas-injected FPE - Foam Polyethylene |
.144 |
|
Outer Shield
Outer Shield Material:
| Layer # |
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
| 1 |
Duofoil® |
Tape |
Aluminum Foil-Polyester Tape-Aluminum Foil |
100 |
| 2 |
|
Braid |
AL - Aluminum |
40 |
|
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material |
| PVC - Polyvinyl Chloride |
|
Overall Cable
| Overall Nominal Diameter: |
0.237 in. |
Mechanical Characteristics (Overall)
| Operating Temperature Range: |
-40°C To +80°C |
| UL Temperature Rating: |
75°C |
| Bulk Cable Weight: |
22 lbs/1000 ft. |
| Max. Recommended Pulling Tension: |
80 lbs. |
| Min. Bend Radius/Minor Axis: |
2.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: |
CATV, CM |
| CEC/C(UL) Specification: |
CM |
| EU Directive 2011/65/EU (ROHS II): |
Yes |
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2002/95/EC (RoHS): |
Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
| EU Directive 2002/96/EC (WEEE): |
Yes |
| EU Directive 2003/11/EC (BFR): |
Yes |
| CA Prop 65 (CJ for Wire & Cable): |
Yes |
| MII Order #39 (China RoHS): |
Yes |
Flame Test
| UL Flame Test: |
UL1685 UL Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) |
| 44.5 |
|
Nominal Outer Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) |
| 17 |
|
Nom. Attenuation:
| Freq. (MHz) |
Attenuation (dB/100 ft.) |
| 5 |
0.75 |
| 55 |
1.84 |
| 211 |
3.36 |
| 270 |
3.79 |
| 300 |
3.99 |
| 350 |
4.33 |
| 400 |
4.66 |
| 450 |
4.96 |
| 550 |
5.48 |
| 750 |
6.51 |
| 870 |
7.00 |
| 1000 |
7.68 |
|
Max. Operating Voltage - UL:
Typical Structural Return Loss:
| Description |
Freq. (MHz) |
Start Freq. (MHz) |
Stop Freq. (MHz) |
Typical SRL (dB) |
| |
|
5 |
550 |
18 |
|
Notes (Overall)
| Notes: |
Sweep tested 5 MHz to 550 MHz. |