商品編號: Belden-1189AP
Belden1189AP RG6 Broadband CATV Coaxial Cable foam FEP insulation, Duobond® IV quad shield (60% and 40% coverage), 100% 鋁箔鋁網屏蔽隔離寬頻有線電視傳輸(鐵氟龍耐燃)同軸電纜
1189AP
 |
|
Coax - Broadband CATV Coaxial Cable
18 AWG solid .040" bare copper-covered steel conductor, foam FEP insulation, Duobond® IV quad shield (60% and 40% coverage), Flamarrest® jacket. |
For more Information
please call
1-800-Belden1 |
| Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
| 1189AP 8771000 |
1,000 FT |
32.000 LB |
NATURAL |
C |
RG-6 PLENUM QUAD SH |
|
| Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical Characteristics (Overall)
Conductor
AWG:
| # Coax |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
| 1 |
18 |
Solid |
BCCS - Bare Copper Covered Steel |
.040 |
|
Insulation
Insulation Material:
| Insulation Material |
Dia. (in.) |
| FFEP - Foam Fluorinated Ethylene Propylene |
.170 |
|
Outer Shield
Outer Shield Material:
| Layer # |
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
| 1 |
Bonded Duofoil® |
Tape |
Bonded Aluminum Foil-Polyester Tape-Aluminum Foil |
100 |
| 2 |
|
Braid |
AL - Aluminum |
60 |
| 3 |
Duofoil® |
Tape |
Aluminum Foil-Polyester Tape-Aluminum Foil |
100 |
| 4 |
|
Braid |
AL - Aluminum |
40 |
|
Outer Jacket
Outer Jacket Material:
| Outer Jacket Trade Name |
Outer Jacket Material |
| Flamarrest® |
LS PVC - Low Smoke Polyvinyl Chloride |
|
Overall Cabling
| Overall Nominal Diameter: |
0.248 in. |
Mechanical Characteristics (Overall)
| Operating Temperature Range: |
-20°C To +75°C |
| Bulk Cable Weight: |
39 lbs/1000 ft. |
| Max. Recommended Pulling Tension: |
137 lbs. |
| Min. Bend Radius (Install)/Minor Axis: |
2.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: |
CMP, CATVP |
| CEC/C(UL) Specification: |
CMP |
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2002/95/EC (RoHS): |
Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): |
04/01/2005 |
| EU Directive 2002/96/EC (WEEE): |
Yes |
| EU Directive 2003/11/EC (BFR): |
Yes |
| CA Prop 65 (CJ for Wire & Cable): |
Yes |
| MII Order #39 (China RoHS): |
Yes |
Flame Test
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) |
| 28.0 |
|
Nominal Outer Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) |
| 4.8 |
|
Nom. Attenuation:
| Freq. (MHz) |
Attenuation (dB/100 ft.) |
| 1 |
.3 |
| 10 |
.66 |
| 50 |
1.6 |
| 100 |
2.2 |
| 200 |
3.0 |
| 400 |
4.6 |
| 700 |
6.6 |
| 900 |
7.7 |
| 1000 |
8.2 |
|
Max. Operating Voltage - UL:
Minimum Structural Return Loss:
| Description |
Freq. (MHz) |
Start Freq. (MHz) |
Stop Freq. (MHz) |
Min. SRL (dB) |
| |
|
5 |
1000 |
20 |
|
Notes (Overall)
| Notes: |
Sweep tested 5 MHz to 1 GHz. |
|