9221  | | Coax - 75 Ohm Miniature Coax 30 AWG stranded (7x38) .012" tinned copper conductor, foam HDPE insulation, tinned copper braid shield (89% coverage), PVC jacket. | For more Information please call 1-800-Belden1 |
| Item # | Putup | Ship Weight | Color | Notes | Item Desc | | 9221 010U500 | 500 FT | 4.000 LB | BLACK | | 75 OHM MINIATURE COAX | | 9221 010100 | 100 FT | 1.400 LB | BLACK | | 75 OHM MINIATURE COAX | | 9221 010500 | 500 FT | 4.000 LB | BLACK | | 75 OHM MINIATURE COAX | |
Physical Characteristics (Overall)
Conductor
AWG:
| # Coax | AWG | Stranding | Conductor Material | Dia. (in.) | | 1 | 30 | 7x38 | TC - Tinned Copper | .012 | |
Insulation
Insulation Material:
| Insulation Material | Dia. (in.) | | FHDPE - Foam High Density Polyethylene | .058 | |
Outer Shield
Outer Shield Material:
| Type | Outer Shield Material | Coverage (%) | | Braid | TC - Tinned Copper | 89 | |
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material | | PVC - Polyvinyl Chloride | |
Overall Cabling
| Overall Nominal Diameter: | 0.097 in. |
Mechanical Characteristics (Overall)
| Operating Temperature Range: | -40°C To +60°C |
| UL Temperature Rating: | 60°C (UL AWM Style 1375) |
| Bulk Cable Weight: | 6 lbs/1000 ft. |
| Max. Recommended Pulling Tension: | 14 lbs. |
| Min. Bend Radius (Install)/Minor Axis: | 1 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| AWM Specification: | UL Style 1375 (30 V 60°C) |
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2002/95/EC (RoHS): | Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
| EU Directive 2002/96/EC (WEEE): | Yes |
| EU Directive 2003/11/EC (BFR): | Yes |
| CA Prop 65 (CJ for Wire & Cable): | Yes |
| MII Order #39 (China RoHS): | Yes |
Suitability
| Suitability - Indoor: | Yes |
| Suitability - Outdoor: | Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 100 | |
Nominal Outer Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 11.65 | |
Nom. Attenuation:
| Freq. (MHz) | Attenuation (dB/100 ft.) | | 1 | .7 | | 3.6 | 1.3 | | 5 | 1.6 | | 7 | 1.9 | | 9 | 2.1 | | 10 | 2.2 | | 50 | 5.1 | | 70 | 6.1 | | 100 | 7.3 | | 200 | 10.5 | | 400 | 15.5 | | 700 | 21.5 | | 900 | 24.8 | | 1000 | 26.6 | |
Max. Operating Voltage - UL:
| Voltage | | 30 V RMS (UL AWM Style 1375) | |