1426A  | | Coax - 75 Ohm Coax 20 AWG Solid .032" bare copper conductor, gas-injected foam HDPE insulation, bare copper braid shield (95% coverage), PVC jacket. | For more Information please call 1-800-Belden1 |
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 1426A 010U1000 | 1,000 FT | 37.000 LB | BLACK | | #20 PE/GIFHDLDPE BRD PVC | |
Physical Characteristics (Overall)
Conductor
AWG:
# Coax | AWG | Stranding | Conductor Material | Dia. (in.) | 1 | 20 | Solid | BC - Bare Copper | .032 | |
Insulation
Insulation Material:
Insulation Material | Dia. (in.) | Gas-injected FHDPE - Foam High Density Polyethylene | .145 | |
Outer Shield
Outer Shield Material:
Type | Outer Shield Material | Coverage (%) | Braid | BC - Bare Copper | 95 | |
Outer Jacket
Outer Jacket Material:
Outer Jacket Material | PVC - Polyvinyl Chloride | |
Overall Cabling
Overall Nominal Diameter: | 0.242 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: | -30°C To +75°C |
UL Temperature Rating: | 60°C |
Non-UL Temperature Rating: | 75°C |
Bulk Cable Weight: | 36 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 68 lbs. |
Min. Bend Radius (Install)/Minor Axis: | 2.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: | CM |
AWM Specification: | UL Style 1354 |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test
UL Flame Test: | UL1685 UL Loading |
Suitability
Suitability - Indoor: | Yes |
Suitability - Outdoor: | Yes |
Suitability - Aerial: | Yes - When supported by a messenger wire. |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 10.0 | |
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 2.6 | |
Nom. Attenuation:
Freq. (MHz) | Attenuation (dB/100 ft.) | 1 | .3 | 5 | .65 | 10 | .9 | 50 | 1.9 | 100 | 2.6 | 200 | 3.6 | 400 | 5.0 | 700 | 7.0 | 900 | 8.0 | 1000 | 8.5 | |
Max. Operating Voltage - UL:
Voltage | 30 V RMS (UL AWM Style 1354) | 300 V RMS (CM) | |
Max. Operating Voltage - Non-UL: