9267  | | Coax - RG-59/U Type 20 AWG solid .032" bare copper conductor, gas-injected foam high density polyethylene insulation, paper tape separator, bare copper braid shields (95% coverage), Hypalon® jacket. | For more Information please call 1-800-Belden1 |
| Item # | Putup | Ship Weight | Color | Notes | Item Desc | | 9267 0101000 | 1,000 FT | 77.000 LB | BLACK | C | #20 FPE BRD PE BRD CSM | | 9267 010500 | 500 FT | 39.500 LB | BLACK | C | #20 FPE BRD PE BRD CSM | |
| Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
| # Coax | AWG | Stranding | Conductor Material | Dia. (in.) | | 1 | 20 | Solid | BC - Bare Copper | .032 | |
Insulation
Insulation Material:
| Insulation Material | Dia. (in.) | | Gas-injected FHDPE - Foam High Density Polyethylene | .145 | |
Inner Shield
Inner Shield Material:
| Type | Inner Shield Material | Coverage (%) | | Braid | BC - Bare Copper | 95 | |
Inner Jacket
Inner Jacket Material:
| Inner Jacket Material | Nom. Dia. (in.) | | PE - Polyethylene | .216 | |
Outer Shield
Outer Shield Material:
| Type | Outer Shield Material | Coverage (%) | | Braid | BC - Bare Copper | 80 | |
Outer Jacket
Outer Jacket Material:
| Outer Jacket Trade Name | Outer Jacket Material | | Hypalon® | Chlorosulphonated Polyethylene | |
| Outer Jacket Separator Material: | Paper tape |
Overall Cabling
| Overall Nominal Diameter: | 0.360 in. |
Mechanical Characteristics (Overall)
| Operating Temperature Range: | -20°C To +80°C |
| Non-UL Temperature Rating: | 80°C |
| Bulk Cable Weight: | 72 lbs/1000 ft. |
| Max. Recommended Pulling Tension: | 124 lbs. |
| Min. Bend Radius (Install)/Minor Axis: | 3.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2002/95/EC (RoHS): | Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
| EU Directive 2002/96/EC (WEEE): | Yes |
| EU Directive 2003/11/EC (BFR): | Yes |
| CA Prop 65 (CJ for Wire & Cable): | Yes |
| MII Order #39 (China RoHS): | Yes |
Flame Test
Suitability
| Suitability - Indoor: | Yes |
| Suitability - Outdoor: | Yes |
| Suitability - Aerial: | Yes - When supported by a messenger wire |
| Suitability - Burial: | Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 10.1 | |
Nom. Inner Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 2.5 | |
Nominal Outer Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 2.6 | |
Nom. Attenuation:
| Freq. (MHz) | Attenuation (dB/100 ft.) | | 1 | 0.3 | | 3.6 | 0.6 | | 10 | 0.9 | | 71.5 | 2.1 | | 135 | 2.9 | | 270 | 4.2 | | 360 | 4.8 | | 540 | 6.0 | | 720 | 6.7 | | 750 | 6.9 | | 1000 | 8.3 | | 1500 | 10.5 | | 2250 | 13.4 | | 3000 | 15.9 | |
Max. Operating Voltage - Non-UL:
Minimum Structural Return Loss:
| Start Freq. (MHz) | Stop Freq. (MHz) | Min. SRL (dB) | | 5 | 850 | 21 | | 851 | 3000 | 15 | |
Sweep Test
| Sweep Testing: | 100% Sweep tested 5 MHz to 3 GHz. |