9232  | | Coax - RG-11/U Type 15 AWG stranded (19x27) .064" bare copper conductor, foam HDPE insulation, paper tape separator, bare copper braid shields (90% coverage), Hypalon® jacket. | For more Information please call 1-800-Belden1 |
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 9232 0101000 | 1,000 FT | 145.000 LB | BLACK | C | 75 OHM TRIAX | 9232 010500 | 500 FT | 76.500 LB | BLACK | C | 75 OHM TRIAX | |
Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Coax | AWG | Stranding | Conductor Material | Dia. (in.) | 1 | 15 | 19x27 | BC - Bare Copper | .064 | |
Insulation
Insulation Material:
Insulation Material | Dia. (in.) | Gas-injected FHDPE - Foam High Density Polyethylene | .312 | |
Inner Shield
Inner Shield Material:
Type | Inner Shield Material | Coverage (%) | Braid | BC - Bare Copper | 90 | |
Inner Jacket
Inner Jacket Material:
Inner Jacket Material | Nom. Dia. (in.) | PE - Polyethylene | .391 | |
Outer Shield
Outer Shield Material:
Type | Outer Shield Material | Coverage (%) | Braid | BC - Bare Copper | 82 | |
Outer Shield Separator Material: | Paper Tape |
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name | Outer Jacket Material | Hypalon® | Chlorosulphonated Polyethylene | |
Overall Cabling
Overall Nominal Diameter: | 0.520 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: | -20°C To +75°C |
UL Temperature Rating: | 60°C |
Non-UL Temperature Rating: | 75°C |
Bulk Cable Weight: | 135 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 239 lbs. |
Min. Bend Radius (Install)/Minor Axis: | 5.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
AWM Specification: | UL Style 1641 (30 V 60°C) |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test
UL Flame Test: | UL1685 UL Loading, VW-1 |
Suitability
Suitability - Indoor: | Yes |
Suitability - Outdoor: | Yes |
Suitability - Burial: | Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 3.1 | |
Nom. Inner Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 1.6 | |
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 1.6 | |
Nom. Attenuation:
Freq. (MHz) | Attenuation (dB/100 ft.) | 1.000 | 0.100 | 3.600 | 0.300 | 10.000 | 0.500 | 71.500 | 1.200 | 135.000 | 1.800 | 270.000 | 2.600 | 360.000 | 3.100 | 540.000 | 3.900 | 720.000 | 4.700 | 750.000 | 4.800 | 1000.000 | 5.700 | |
Max. Operating Voltage - UL:
Max. Operating Voltage - Non-UL:
Other Electrical Characteristic 1: | Nominal Capacitance 1st Shield to 2nd Shield: 205 pf/ft. |
Other Electrical Characteristic 2: | Nominal Voltage Breakdown: 20K V RMS |
Minimum Return Loss:
Description | Freq. (MHz) | Start Freq. (MHz) | Stop Freq. (MHz) | Min. RL (dB) | | | 5 | 450 | 21 | |
Sweep Test
Sweep Testing: | 100% sweep tested 5 MHz to 450 MHz. |
Misc. Information (Overall)
Notes (Overall)
Notes: | Hypalon is a DuPont trademark. |