8232A  | | Coax - RG-59/U Type 20 AWG solid .032" bare copper conductor, gas-injected foam HDPE insulation, bare copper braid shields (95% coverage), PVC jacket. | For more Information please call 1-800-Belden1 |
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 8232A 0101000 | 1,000 FT | 68.000 LB | BLACK | C | #20 GIFHDLDPE BRD PVC BRD PVC | |
Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Coax | AWG | Stranding | Conductor Material | Dia. (in.) | 1 | 20 | Solid | BC - Bare Copper | .032 | |
Insulation
Insulation Material:
Insulation Material | Dia. (in.) | Gas-injected FHDPE - Foam High Density Polyethylene | .145 | |
Inner Shield
Inner Shield Material:
Type | Inner Shield Material | Coverage (%) | Braid | BC - Bare Copper | 95 | |
Inner Jacket
Inner Jacket Material:
Inner Jacket Material | Nom. Dia. (in.) | PVC - Polyvinyl Chloride | .225 | |
Outer Shield
Outer Shield Material:
Type | Outer Shield Material | Coverage (%) | Braid | BC - Bare Copper | 80 | |
Outer Jacket
Outer Jacket Material:
Outer Jacket Material | PVC - Polyvinyl Chloride | |
Overall Cabling
Overall Nominal Diameter: | 0.315 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: | -40°C To +75°C |
UL Temperature Rating: | 60°C |
Non-UL Temperature Rating: | 75°C |
Bulk Cable Weight: | 63 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 125 lbs. |
Min. Bend Radius (Install)/Minor Axis: | 3.250 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: | CMR |
CEC/C(UL) Specification: | CMG |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test
UL Flame Test: | UL1666 Vertical Shaft |
Suitability
Suitability - Indoor: | Yes |
Suitability - Outdoor: | Yes |
Suitability - Aerial: | Yes - When supported by a messenger wire |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 10.0 | |
Nom. Inner Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 2.5 | |
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 2.8 | |
Nom. Attenuation:
Freq. (MHz) | Attenuation (dB/100 ft.) | 1 | .3 | 3.6 | .6 | 10 | .9 | 71.5 | 2.1 | 135 | 3.0 | 270 | 4.2 | 360 | 4.8 | 540 | 5.9 | 720 | 7.0 | 750 | 7.1 | 1000 | 8.3 | 1500 | 10.5 | 2250 | 13.4 | 3000 | 15.9 | |
Max. Operating Voltage - UL:
Minimum Structural Return Loss:
Start Freq. (MHz) | Stop Freq. (MHz) | Min. SRL (dB) | 5 | 850 | 21 | 851 | 3000 | 15 | |
Sweep Test
Sweep Testing: | 100% sweep tested 5 MHz to 3 GHz. |