9290  | | Coax - 75 Ohm Coax 18 AWG solid .037" bare copper conductor, foam polyethylene insulation, double bare copper braid shields (98% coverage), PVC jacket. | For more Information please call 1-800-Belden1 |
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 9290 0101000 | 1,000 FT | 59.000 LB | BLACK | C | RG-6/U TYPE COAX | 9290 0102000 | 2,000 FT | 118.000 LB | BLACK | C | RG-6/U TYPE COAX | |
Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Coax | AWG | Stranding | Conductor Material | Dia. (in.) | 1 | 18 | Solid | BC - Bare Copper | .037 | |
Insulation
Insulation Material:
Insulation Material | Dia. (in.) | FPE - Foam Polyethylene | .180 | |
Outer Shield
Outer Shield Material:
Layer # | Type | Outer Shield Material | Coverage (%) | 1 | Braid | BC - Bare Copper | 95 | 2 | Braid | BC - Bare Copper | 95 | |
Outer Jacket
Outer Jacket Material:
Outer Jacket Material | PVC - Polyvinyl Chloride | |
Overall Cabling
Overall Nominal Diameter: | 0.288 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: | -40°C To +80°C |
Non-UL Temperature Rating: | 80°C |
Bulk Cable Weight: | 54 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 108 lbs. |
Min. Bend Radius (Install)/Minor Axis: | 2.800 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: | CM |
CEC/C(UL) Specification: | CM |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test
UL Flame Test: | UL1685 UL Loading |
Suitability
Suitability - Indoor: | Yes |
Suitability - Outdoor: | Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 7.5 | |
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 2 | |
Nom. Attenuation:
Start Freq. (MHz) | Attenuation (dB/100 ft.) | 1 | .2 | 10 | .7 | 50 | 1.7 | 100 | 2.5 | 200 | 3.6 | 400 | 5.0 | 700 | 7.2 | 900 | 8.3 | 1000 | 8.8 | |
Max. Operating Voltage - UL:
Minimum Return Loss:
Description | Freq. (MHz) | Start Freq. (MHz) | Stop Freq. (MHz) | Min. RL (dB) | | | 5 | 450 | 23 | |