9231  | | Coax - RG-59/U Type 20 AWG solid .031" bare copper conductor, polyethylene insulation, tinned copper/bare copper braid shield (98% coverage), PVC jacket. | For more Information please call 1-800-Belden1 |
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 9231 0081000 | 1,000 FT | 76.000 LB | GRAY | C | #20 PE DBL BRD PVC | 9231 008500 | 500 FT | 39.000 LB | GRAY | | #20 PE DBL BRD PVC | |
Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Coax | AWG | Stranding | Conductor Material | Dia. (in.) | 1 | 20 | Solid | BC - Bare Copper | .031 | |
Insulation
Insulation Material:
Insulation Material | Dia. (in.) | PE - Polyethylene | .198 | |
Outer Shield
Outer Shield Material:
Layer # | Type | Outer Shield Material | Coverage (%) | 1 | Braid | TC - Tinned Copper | 98 | 2 | Braid | TC - Tinned Copper | 95 | |
Outer Jacket
Outer Jacket Material:
Outer Jacket Material | PVCNC - Polyvinyl Chloride Non-Contaminating | |
Overall Cabling
Overall Nominal Diameter: | 0.305 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: | -40°C To +60°C |
UL Temperature Rating: | 60°C |
Bulk Cable Weight: | 71 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 168 lbs. |
Min. Bend Radius (Install)/Minor Axis: | 3 in. |
Min. Bend Radius (Continuous Flexing): | 6 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: | CMH |
CEC/C(UL) Specification: | CMH |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 10/01/2005 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test
UL Flame Test: | UL1685 UL Loading, VW-1 |
Suitability
Suitability - Indoor: | Yes |
Suitability - Outdoor: | Yes |
Suitability - Aerial: | Yes - When supported by a messenger wire |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 9.9 | |
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 1.1 | |
Nom. Attenuation:
Freq. (MHz) | Attenuation (dB/100 ft.) | 1 | 0.3 | 3.6 | 0.5 | 10 | 0.8 | 71.5 | 2.0 | 135 | 3.5 | 270 | 4.3 | 360 | 5.0 | 540 | 6.2 | 720 | 7.2 | 750 | 7.4 | 1000 | 9.1 | |
Max. Operating Voltage - UL:
Max. Operating Voltage - Non-UL:
Other Electrical Characteristic 1: | Impedance tested in accordance with ASTM D-4566 paragraph 43.2, option 2 using a 75 Ohm fixed bridge and termination. 75 +/- 1.5 Ohms |
Other Electrical Characteristic 2: | Return Loss tested in accordance with ASTM D-4566 paragraph 45.3, using a 75 ohm fixed bridge and termination. 720A Series is available by special request. |
Minimum Return Loss:
Start Freq. (MHz) | Stop Freq. (MHz) | Min. RL (dB) | 5 | 216 | 27 | 217 | 850 | 23 | |
Sweep Test
Sweep Testing: | 100% sweep tested. 5 Mhz to 850 MHz. |
Notes (Overall)
Notes: | Non-Plenum versions comply with Telcordia Specification GR-139-CORE. |