8215  | | Coax - 75 Ohm Coax 21 AWG solid .028" bare copper-covered steel conductor, polyethylene insulation, double bare copper braid shields (98% coverage), polyethylene jacket. | For more Information please call 1-800-Belden1 |
| Item # | Putup | Ship Weight | Color | Notes | Item Desc | | 8215 0101000 | 1,000 FT | 74.000 LB | BLACK | C | RG-6A/U TYPE COAX | |
| Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
| # Coax | AWG | Stranding | Conductor Material | Dia. (in.) | | 1 | 21 | Solid | BCCS - Bare Copper Covered Steel | .028 | |
Insulation
Insulation Material:
| Insulation Material | Dia. (in.) | | PE - Polyethylene | .185 | |
Outer Shield
Outer Shield Material:
| Layer # | Type | Outer Shield Material | Coverage (%) | | 1 | Braid | BC - Bare Copper | 96 | | 2 | Braid | BC - Bare Copper | 96 | |
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material | | PE - Polyethylene | |
Overall Cabling
| Overall Nominal Diameter: | 0.332 in. |
Mechanical Characteristics (Overall)
| Operating Temperature Range: | -55°C To +80°C |
| Non-UL Temperature Rating: | 80°C |
| Bulk Cable Weight: | 69 lbs/1000 ft. |
| Max. Recommended Pulling Tension: | 180 lbs. |
| Min. Bend Radius (Install)/Minor Axis: | 3.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2002/95/EC (RoHS): | Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
| EU Directive 2002/96/EC (WEEE): | Yes |
| EU Directive 2003/11/EC (BFR): | Yes |
| CA Prop 65 (CJ for Wire & Cable): | Yes |
| MII Order #39 (China RoHS): | Yes |
Suitability
| Suitability - Indoor: | Yes |
| Suitability - Outdoor: | Yes |
| Suitability - Burial: | Yes |
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 32.0 | |
Nominal Outer Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 1.1 | |
Nom. Attenuation:
| Freq. (MHz) | Attenuation (dB/100 ft.) | | 1 | .4 | | 10 | .8 | | 50 | 1.9 | | 100 | 2.7 | | 200 | 4.1 | | 400 | 5.9 | | 700 | 8.1 | | 900 | 9.4 | | 1000 | 9.8 | |
Max. Operating Voltage - Non-UL:
Minimum Return Loss:
| Description | Freq. (MHz) | Start Freq. (MHz) | Stop Freq. (MHz) | Min. RL (dB) | | | | 5 | 450 | 23 | |
Sweep Test
| Sweep Testing: | 100% Sweep tested 5 MHz to 450 MHz. |