    首頁 > > An-Armor Cable Teck 90 & Accessories 金屬鎧裝電纜

    A-TECK 90 (CSA) XLPE/Galv. Steel or Aluminum Armor/PVC 600V -40°C to 90°C 12 AWG & 10 Awg多芯波紋鋁管or波紋鋼管鎧裝儀錶電力控制電纜
    看原圖
    5260305




    商品編號: A-7TE-1203

    A-TECK 90 (CSA) XLPE/Galv. Steel or Aluminum Armor/PVC 600V -40°C to 90°C 12 AWG & 10 Awg多芯波紋鋁管or波紋鋼管鎧裝儀錶電力控制電纜


    For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry
    locations. For direct earth burial. Typical applications are for power, lighting and control circuits in: pulp and paper mills, steel mills, food processing plants, commercial
    centers, mines, generating stations, refineries, industrial plants and chemical plants.




    ★★★★商品說明★★★★

    Armored Cable
    Teck 90 (CSA)

    600 V 12 AWG Multiconductor

    Galvanized steel or aluminum armor
    XLP insulation
    Inner and outer PVC jackets, interlocked armor


    SPECIFICATIONS
    1. CONDUCTOR:
    Class B stranded, bare, soft copper
    2. INSULATION:Cross-Linked Polyethylene (XLP) as approved by CSA on Types RW90 XLP -40°C per CSA C22.2,
    No. 131, color code: 2/C black, white; 3/C red, black, blue; 4/C red, black, blue, white; more than 4/C numbered
    3. GROUNDING CONDUCTOR: 14 AWG uninsulated Class B stranded grounding conductor is included in the cable assembly
    4. ASSEMBLY: Multiple conductor cables are assembled with suitable fillers and binder tape
    5. INNER JACKET:Polyvinyl Chloride (PVC) heat-, flame- and moisture-resistant jacket, rated -40°C
    6. ARMOR: Aluminum or galvanized steel interlocking armor
    7. OVERALL JACKET: Polyvinyl Chloride (PVC) heat-, flame- and moisture-resistant jacket, rated -40°C, the standard color is black but colored jackets are available on request.
    Cable meets Ontario Hydro Spec. L-891 SM-77 flame test and FT4 vertical tray flame test
    8. AMPACITY: Based on 90°C column of Table 2 of the 2009 Canadian Electric Code, allowable ampacities for not more than 3 copper conductors in raceway or cable based on
    30°C ambient temperature. Ampacity correction factors for number of conductors from Table 5C of the CEC
    9. TEMPERATURE: -40°C to 90°C
    10.VOLTAGE: 600 V


    APPLICATIONS
    For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry
    locations. For direct earth burial. Typical applications are for power, lighting and control circuits in: pulp and paper mills, steel mills, food processing plants, commercial
    centers, mines, generating stations, refineries, industrial plants and chemical plants.