    商品編號: Belden-5000FE

    Belden-Riser Shielded CMR/CL3R Security Low-voltage Cable 低壓 鋁箔隔離安全監控電纜線


    NEC: CMR (22-16 AWG), CL3R (14-12 AWG), and FPLR (2C 12 AWG and 2C 14 AWG) when jacket is red



    ★★★★商品說明★★★★

    Security Low-voltage Cable
    Belden New Generation

    Riser Shielded CMR/CL3R

    Power limited circuit and communications cable for riser and conduit. For use in remote control,
    signaling, security systems, communications, intercom/P.A. systems, sound/audio and nurse call.
     

    SPECIFICATIONS
    1. CONDUCTOR: Solid or stranded bare copper
    2. INSULATION: Polyvinyl chloride (PVC) or polypropylene (PP)
    3. SHIELDING:Beldfoil shield applied overall with a drain wire
    4. JACKET: Gray polyvinyl chloride (PVC) with rip cord
    5. STANDARDS: NEC: CMR (22-16 AWG), CL3R (14-12 AWG), and FPLR (2C 12 AWG and 2C 14 AWG) when jacket is red
    6. TEMPERATURE: 75°C



    ★★★★使用操作說明★★★★

    To ensure optimum security
    installation performance,
    be sure to use the watchdog
    of the industry: Belden®
    New Generation® cables.

     

    A system failure, or interruption of signal, can be
    a catastrophic occurrence in any security
    installation. That’s why you need Belden New
    Generation cables, a product line recognized the
    world over for its quality and reliability.
     

    The New Generation line also represents one of
    the largest, most economical and up-to-date
    selections of multi-conductor and coaxial
    products on the market today: a full complement
    of cables for access control, CCTV, computer
    interconnect, alarm, fire alarm and other security
    applications — complete with water-blocked
    options for installation in intermittently
    wet environments.
     

    New Generation cables also offer installerfriendly
    features such as:
    • NEC riser and plenum rated; UL and
    C(UL) listed as applicable.
    • A unique composite cable design,
    Access Control Banana Peel® strips
    away installation time and labor.
    • Rip cords for easy jacket removal and
    sequential footage markings on the jacket to
    eliminate guesswork and waste.
    For space savings and to help eliminate waste,
    many product codes also are available with
    Belden’s new Belcoil® packaging —
    a revolutionary new tangle-proof
    packaging concept.