    CCI-7230 22/8 STRANDED CL3P/CMP/FPLP PLENUM CABLE Awg22 x 8c 低煙PVC  影音 醫院護理呼叫系統 安全監控用線
    看原圖
    5555732




    商品編號: CCI-72308

    CCI-7230 22/8 STRANDED CL3P/CMP/FPLP PLENUM CABLE Awg22 x 8c 低煙PVC 影音 醫院護理呼叫系統 安全監控用線


      72308 - 22/8 STRANDED BC CMP/CL3P
    MULTI-CONDUCTOR PLENUM NON-SHIELDED CMP Plenum Multi-Conductor Electronic Wire (Unshielded)

    Features:

    • Low Smoke PVC jacket
    • Ripcord and Sequential Footage Marking
    • Temperature Rating of 75°C

    Applications:

    • Power limited circuit and communication cable for use in plenum applications
    • Remote Control, Signaling, Security Systems, Communications, Intercom/P.A. Systems, Sound/Audio, and Nurse Call

    Industry Approvals:

    • UL Type CMP/CL3P / cUL Type CMP/FT6
    • NEC Article 725 & 800
    • California State Fire Marshall



    ★★★★商品說明★★★★

    PART NUMBER: 72308

    DESCRIPTION: 22/8 STRANDED CL3P/CMP/FPLP PLENUM CABLE

    CONSTRUCTION: This cable consists of eight bare copper insulated conductors and an overall jacket.

    APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800.

    APPLICATION: Power Limited Circuit Cable and Communications Cable Used in Plenum Applications

     

    Construction Parameters:

    Conductor 22 AWG Bare Copper

    Stranding 7/30

    Insulation Material Low Smoke PVC

    Insulation Thickness 0.006 Nom.

    Insulated Conductor Diameter 0.041 Nom.

    Number of Conductors 8

    Lay Length 5.00 Nom.

    Jacket Material PVC

    Jacket Thickness 0.014 Nom.

    Overall Cable Diameter 0.164 Nom.

    Approximate Cable Weight 27.1 Lbs/1M Nom.

    Flame Rating NFPA 262 Steiner Tunnel Smoke and Flame Test

     

    Electrical Properties:

    Temperature Rating -20OC to 75OC

    Operating Voltage 300V Max per NEC Article 800

    Capacitance Between Conductors @ 1 KHz 31 pF/ft Nom.

    Capacitance Between Conductors to Shield @ 1 KHz ---

    DC Resistance per Conductor @ 20OC 16.19 Ohms/1M Nom.

     

    Insulation Colors Black Red White Green Brown Blue Orange Yellow

    Jacket Color Beige

    Legend (Surface Ink Print) COLEMAN CABLE 72308 22 AWG 8/C C(ETL) US (ETL CODE) TYPE CMP/CL3P/FPLP 75C

    --- TYPE CMP FT6