    CALEDONIAN-Fire resistant Multi Loose Tube Fiber Optic cables 鬆式多芯多套管雲母帶耐火級低煙無毒鎧裝光纖電纜線
    看原圖
    5544251




    商品編號: CALEDONIAN-MLA-B-C-D-F-H-J-FR

    CALEDONIAN-Fire resistant Multi Loose Tube Fiber Optic cables 鬆式多芯多套管雲母帶耐火級低煙無毒鎧裝光纖電纜線


    Application
    The multi loose tube non metallic cables are designed for outside plant, which is prone to electrical interference. They are mainly installed inside buildings, tunnels,subways or closed areas in general, specially designed to guarantee the signal transmission even in case of fire. The cable can also be used for direct burial for armoured version.
    Standards
    Basic design to Telcordia GR-20 / RUS 7 CFR 1755.900 (REA PE-90) / ICEA S 87-640
     




    ★★★★商品說明★★★★

    PRODUCTS

    Fire Resistant Optic Fiber Cables
    Fire resistant Multi Loose Tube Fiber Optic cables
    Application
    The multi loose tube non metallic cables are designed for outside plant, which is prone to electrical interference. They are mainly installed inside buildings, tunnels,subways or closed areas in general, specially designed to guarantee the signal transmission even in case of fire. The cable can also be used for direct burial for armoured version.
    Standards
    Basic design to Telcordia GR-20 / RUS 7 CFR 1755.900 (REA PE-90) / ICEA S 87-640
    FIRE PERFORMANCE

    Circuit Integrity

    IEC 60331-25; BS 6387 CWZ; DIN VDE 0472-814(FE180);

    CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3);

    NF C32-070-2.3(CR1)

    System circuit integrity

    DIN 4102-12, E30 depending on lay system

    Flame Retardance (Single Vertical Wire Test)

    EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);

    CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

    Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)

    EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

    Halogen Free

    IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1;

    CEI 20-37/2-1 ; BS 6425-1*

    No Corrosive Gas Emission

    IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2;

    CEI 20-37/2-2 ; BS 6425-2*

    Minimum Smoke Emission

    IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2;

    CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

    No Toxic gases

    NES 02-713; NF C 20-454

    Note: Asterisk * denotes superseded standard.
    CABLE CONSTRUCTION
    Fibers: Singlemode and multimode fibers, with loose tube technology.
    Structure: The cable consists of 5 to 36 fibers containing tubes or fillers stranded in up to 3 layers around a central strength member and bound under a LSZH sheath. Each tube contains 4 -12 fibers, which is filled with water blocking gel.
    Central Strength Member: Solid or stranded steel wire coated with polyethylene is usually used as central strength member. Fiber glass reinforced plastics (FRP) will be used as central strength member if non metallic construction is required.
    Fire Barrier: The jelly filled tubes containing the fibers are individually wound with fire blocking mica glass tape and are cabled around a central strength member
    Water Blocking: The jelly filled tube is waterblocked by using swellable tape and thread.
    Reinforcement: Either aramid yarn or fiber glass is wound around the tube to provide physical protection and tensile strength, with added fire protection.
    Inner Sheath (optional): The cable can be jacketed with either PE or Thermoplastic LSZH inner sheath. PE is the preferred option in outdoor environment for water protection purpose.
    Armouring(optional): For diect burial, either galvanized steel wire braid, corrugated steel tape armour or galvanized steel wire armour is applied over an inner polyethylene or LSZH sheath. For steel tape armour, the 0.15mm thick steel tape is coated with a copolymer and applied with an overlap. For steel wire braid or armour, single layer of galvanized steel wire braid or armour is applied.
    Moisture Barrier Tape (optional): An aluminum moisture tape can be incorporated under the sheath for water blocking and shielding purpose.
    Ripcord (optional): An optional ripcord can be located under the jacket to facilitate jacket removal.
    Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1(Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)


     



    ★★★★使用操作說明★★★★

    TYPE CODEs

    MLA-B-CxD-E-F-G-H-I-FR

    FR: Fire Resisting

    Water blocking gel in tubes

     

    X: No water-blocking J: Water blocking gel between jackets; D: Dry water-blocking between cable jackets

    Outer Sheath

    2Y: PE

    Y: PVC

    H: LSZH

    Armour

    Blank: No armour

     

    STA: Corrugated steel tape SWA: Steel wire

     

    SWB: Armour steel wire braided

    Inner Sheath

    2Y: PE

    Y: PVC

    H: LSZH

    Central strength member

    S: Solid steel SR: Stranded steel

     

    F: Fiber reinforced plastic(FRP)

     

    Fiber per tubes: 2-12C No of tubes: 1-36

    Fiber Type

    4: 50/125 um(OM3) 7: NZDS SM fiber per ITU-T G.656

    5: 50/125 um(OM2) 8: NZDS SM fiber per ITU-T G.655

    6: 62.5/125um(OM1) 9: Standard SM fiber per ITU-T G.652.D

    Loose Tube Diameter

    A:2.0mm D: 3.0mm

    B:2.5mm E: 3.2mm

    C: 2.8mm