1. CALEDONIAN-Fire Resistant Coaxial Cables 耐火級低煙無毒同軸電纜線
    CALEDONIAN-Fire Resistant Fire Alarm Cables (950°C 180 minutes)耐火級低煙無毒火警警報電纜線
    Caledonian-Fire Resistant Instrumentation Cables (950°C 180 minutes) 耐火級低煙無毒儀表控制電纜線
    CALEDONIAN-Fire Resistant Optic Fiber Cables 耐火級低煙無毒光纖電纜線
    Caledonian-Fire Resistant Power & Control Cables (950°C 180 minutes) 耐火級低煙無毒電力控制電纜線
    MICC/TRM/TET-Mineral Insulated Heating Units & Cable
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > Caledonian-Fire Resistant Instrumentation Cables (950°C 180 minutes) 耐火級低煙無毒儀表控制電纜線

    CALEDONIAN-Fire Resistant RS485 Databus Cables Mica Glass Tape+PE/PE+Silicone Rubber Insulation + LSFH (950°C 180 minutes) 多對型雲母帶耐火級低煙無毒 RS-485 資料傳輸電纜線
    看原圖
    5544246




    商品編號: CALEDONIAN-RE-RS485

    CALEDONIAN-Fire Resistant RS485 Databus Cables Mica Glass Tape+PE/PE+Silicone Rubber Insulation + LSFH (950°C 180 minutes) 多對型雲母帶耐火級低煙無毒 RS-485 資料傳輸電纜線


    APPLICATION
    The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.
    STANDARDS
    Basic design to EIA/TIA 485
     




    ★★★★商品說明★★★★

    PRODUCTS

    Fire Resistant Signal & Data Cables
    Fire Resistant RS485 Databus Cables
    APPLICATION
    The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.
    STANDARDS
    Basic design to EIA/TIA 485
    FIRE PERFORMANCE

    Circuit Integrity

    IEC 60331-23; BS 6387 CWZ; DIN VDE 0472-814(FE180);

    CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3);

    NF C32-070-2.3(CR1)

    System circuit integrity

    DIN 4102-12, E30 depending on lay system

    Flame Retardance (Single Vertical Wire Test)

    EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);

    CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

    Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)

    EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

    Halogen Free

    IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1;

    CEI 20-37/2-1 ; BS 6425-1*

    No Corrosive Gas Emission

    IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2;

    CEI 20-37/2-2 ; BS 6425-2*

    Minimum Smoke Emission

    IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2;

    CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

    No Toxic gases

    NES 02-713; NF C 20-454

    Note: Asterisk * denotes superseded standard..
    CABLE CONSTRUCTION
    Multipair RS 485 Overall Screened Databus Cable
    Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.
    Insulation: mica glass tape wrapped with PE or PE wrapped with silicone rubber insulation.
    Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.
    Cabling: Pairs are cabled together in concentric layers.
    Overall screen: Aluminum/polyester tape with tinned copper drain wire.
    Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)
    Multipair RS 485 Overall Double Screened Databus Cable
    Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.
    Insulation: mica glass tape wrapped with PE or PE wrapped with silicone rubber insulation.
    Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.
    Cabling: Pairs are cabled together in concentric layers.
    Overall screen: Aluminium/polyester tape+copper wire braid.
    Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)
    Multipair RS 485 Individual & Overall screened Databus Cable
    Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.
    Insulation: mica glass tape wrapped with PE or PE wrapped with silicone rubber insulation.
    Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.
    Cabling: Pairs are cabled together in concentric layers.
    Individual Screen: Individual aluminium/polyester tape.
    Overall Screen: Copper wire braid.
    outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)
    Multipair RS 485 Overall Screened Databus Cable
    Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.
    Insulation: mica glass tape wrapped with PE or PE wrapped with silicone rubber insulation.
    Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.
    Cabling: Pairs are cabled together in concentric layers.
    Overall Screen: Copper wire braid.
    Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)
    Physical AND THERMAL PROPERTIES
    Temperature range during operation (fixed state): -20°C - +90°C
    Temperature range during installation (mobile state): -5°C - +60°C
    Minimum bending radius: 8 x Overall Diameter
    Electrical Properties

    Dielectric test

    1000 V r.m.s. for 5’ (core-core)

     

    1000 V r.m.s. for 5’ (core-screen)

    Impedance

    120Ω

    Capacitance

    45 nF/km conductor to conductor

     

    90 nF/km conductor to shield