PRODUCTSFire Resistant Power & Control Cables 300/500V SR Insulated Control Cables (2-4 Cores) FFX200 05SZ1-U (PH60) (CU/SR/LSZH 300/500V Class 1) APPLICATION The cables are designed, for use as control cable for emergency services and fire circuit control. STANDARDS Basic design adapted from BS 7629-1 FIRE PERFORMANCE Circuit Integrity | IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); BS 8434-1 (30mins); BS 5839-1 Clause 26 2d; CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1) | Circuit Integrity with mechanical shock | EN 50200(PH60); CEI 20-36/4-0 | Circuit Integrity with mechanical shock & water spray | EN 50200 annex E | System circuit integrity | DIN 4102-12, E30 depending on lay system | Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* | Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 | Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* | No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* | Minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* | No Toxic gases | NES 02-713; NF C 20-454 |
Note: Asterisk * denotes superseded standard. VOLTAGE RATING 300/500 V CABLE CONSTRUCTION Conductors: Plain annealed copper wire, solid according to IEC(EN) 60228 class 1. Insulation: Fire resistant silicone rubber compound type EI2 as per BS 7655-1.1. Cabling: The cores are cabled together in concentric layers with suitable non-hygroscopic fillers. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.) COLOUR CODE Insulation Colour Without earth conductor 2 cores black - blue 3 cores black - blue - brown 4 cores black - blue - brown - black With earth conductor 3 cores black - blue - yellow/green 4 cores black - blue - brown - yellow/green Sheath Colour: Orange (other colors upon request) Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30°C – +90°C Temperature range during installation (mobile state): -20°C – +50°C Minimum bending radius: 6 x Overall Diameter Electrical PROPERTIES Dielectric test: | 2000 V r.m.s. x 5’ (core/core) | Insulation resistance | ≥300 MΩ x km (at 20°C) | Short circuit temperature | 350°C |

|