|
商品編號: An-2A-1003S
AN-2A-1003S Awg 10-3C VNTC STR BC PVC NYL FOIL SHD PVC JKT 600V TC-ER E2 PVC尼龍被覆鋁箔隔離控制電纜 |
|
|
|
|
|
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
 |
|
|
PVC-nylon insulation
PVC jacket
90°C, 600 V |
Tech. Info & Standards:
SPECIFICATIONS:
1. CONDUCTORS: Class B stranded bare copper per UL 83 and 62.
2. INSULATION: Polyvinyl chloride (PVC) per UL 62 for Type TFFN (18-16 AWG) or UL 83 for Type THWN or THHN wire. Average thickness is 15 mils for sizes 18-12 AWG and 20 mils for 10 AWG.
3. INSULATION JACKET: Each insulated conductor is jacketed with nylon meeting UL 62 for Type TFFN or UL 83 for Type THWN or THHN wire. Minimum thickness is 4 mils.
4. COLOR CODE: ICEA Method 1, Table E-2 (formerly K-2).
5. ASSEMBLY: Conductors are cabled with fillers where necessary to make round. Two conductor cables are flat.
6. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC) per UL 1277.
7. STANDARDS: Tested per UL requirements for Type TC cables having THWN or THHN (TFFN) conductors. Cables are listed for direct burial and meet the IEEE 1202, UL 1277 and ICEA 70,000 BTU Flame Tests.
8. AMPACITY: Based on not more than three conductors in receway or cable or earth with an ambient temperature of 30¦C per NEC 310-16. The values have been derated where applicable.
9. TEMPERATURE: 90¦C
10 VOLTAGE: 600V |
Applications:
Designed for power and control, telemetering, relay control, traffic control, switching, lighting and signal transmission. May be used in Class 1, Div. 2 Hazardous Locations per NEC Art. 501. These cables also conform to Art. 318 "Cable Trays" and Art 340 "Power and Control Tray Cable." |
Specifications:
- CONDUCTORS: Class B stranded bare copper per UL 83 and 62
- INSULATION: Polyvinyl Chloride (PVC) per UL 62 for Type TFFN (18-16 AWG) or UL 83 for Type THWN or THHN wire, nominal thickness is 15 mils for sizes 18-12 AWG and 20 mils for 10 AWG
- INSULATION JACKET: Each insulated conductor is jacketed with nylon meeting UL 62 for Type TFFN or UL 83 for Type THWN or THHN wire, minimum thickness is 4 mils
- COLOR CODE: ICEA Method 1, Table E-2 (formerly K-2)
- ASSEMBLY: Conductors are cabled with fillers where necessary to make round, two conductor cables are flat
- OVERALL JACKET: Sunlight-resistant Polyvinyl Chloride (PVC) per UL 1277
- STANDARDS: Meets UL requirements for Type TC cables having THWN or THHN (TFFN) conductors, cables are listed for direct burial and meet the IEEE 1202, UL 1277 and ICEA 70,000 BTU Flame Tests
- AMPACITY: Based on not more than three conductors in raceway or cable or earth with an ambient temperature of 30ºC per NEC Table 310.16, the values have been derated where applicable
- TEMPERATURE: 90ºC
- VOLTAGE: 600 V
|
Description |
10-3C VNTC STR BC PVC NYL FOIL SHD PVC JKT 600V TC-ER E2 |
|
Attributes |
Conductor Size/Gauge: |
10 AWG |
CONDUCTOR: Count |
3 CONDUCTOR |
Type |
STRANDED |
Material |
BARE COPPER |
Voltage Range: |
600 |
Temperature Rating: |
90 DEGREES CENTIGRADE |
INSULATION: Material |
PVC/NYL-PVC/NYLON |
Color Code |
ICEA METHOD 1 - TABLE K2 |
Screen/Shield: |
SHIELDED |
Shield/Screen Type |
FOIL SHIELD AL MYLAR |
JACKETING: Material |
PVC-POLYVINYL CHLORIDE |
Armor: |
NO |
EARTH/GROUND WIRES: |
NO |
Composite: |
NO |
Product Type: |
VNTC CONTROL |
Unspsc Code |
26121603 |
|
|