    RFOU (NEK 606 P1) HALOGEN FREE, LOW SMOKE DENSITY, FLAME RETARDANT POWER CABLE 低煙無鹵,阻燃,銅網隔離電力電纜
    看原圖
    30197785




    商品編號: UNTL-RFOU-P1

    RFOU (NEK 606 P1) HALOGEN FREE, LOW SMOKE DENSITY, FLAME RETARDANT POWER CABLE 低煙無鹵,阻燃,銅網隔離電力電纜



    ★★★★商品說明★★★★

    RFOU (NEK 606 P1)

    HALOGEN FREE, LOW SMOKE DENSITY, FLAME RETARDANT POWER CABLE

    CABLE STRUCTURE
    1- CONDUCTOR : Electrolytic, stranded, tinned copper wire IEC 60228 Class 2 (Class 5 on request).

    2- INSULATION : Halogen free EPR or Halogen free HEPR

    3- BEDDING : Halogen free compound.

    4- SCREEN : Electrolytic, tinned copper braided screen ( 90% coverage ).

    5- OUTER SHEATH : SHF2, Black

    PRODUCTION AND TEST STANDARDS

    CONSTRUCTION : NEK 606 P1, IEC 60092/353

    TESTS AND MATERIAL : IEC 60092 /350-351-359

    FLAME RETARDATION : IEC 60332 /1, IEC 60332 / 3

    HALOGEN CONTENT : IEC 60754 / 1 - 2

     SMOKE DENSITY : IEC 61034 / 1-2 ( DIN EN 50268/1-2)

    WORKING TEMPERATURE : -40°C / + 90°C

    MIN. BENDING RADIUS (FIXED) : (kablo çap›)x 8 x(overall diameter)

    RATED VOLTAGE : 0,6/1 kV T

    TEST VOLTAGE : 3,5 kV

    APPLICATION

    Fixed installation cable for power, control and lighting.

    ENVIRONMENT

    Usable at all conditions in marine environment such as dry, wet or oily locations.

    SAFETY

    Due to its halogen free and flame retardant features, it wont create corrosive gases and prevents the fire from spreading around. Thus it protects human life and equipment, during a fire. Low smoke density reduces the risk of smoke suffocation and keeps visibility around the fire zone.



    ★★★★商品規格描述★★★★

    It includes cables in relation to petroleum and natural gas drilling platform. These cables are produced according to NEK606, IEEE1580 IEC60092/350 and some other standards. We have lots of type approval certificates from ABS, BV, DNV, GL, LR, Class NK, RINA, RMRS, GOST and Turkish Lloyd for our offshore cables.

    它包括相對於石油和天然氣鑽井平台的電纜。這些電纜是根據NEK606,IEEE1580 IEC60092/350和其他一些標準生產。我們有很多來自ABS,BV,DNV,GL,LR,NK級,RINA,RMRS,GOST,為我們的海上電纜的土耳其勞埃德型式認可證書。