HALOGEN FREE, FLAME RETARDANT, INDIVIDUALLY AND OVERALL SCREENED, COMMUNICATION AND SIGNAL CABLE
CABLE STRUCTURE
1- CONDUCTOR : Electrolytic, stranded, annealed copper wire. IEC 60228 Class 2 (Class 5 and/or tinned on request).
2- INSULATION : Halogen free, crosslinked polyethylene compound (XLPE). Layup : Cores laid up in pairs.
3- SEPERATOR : Separating foil over pairs.
4- DRAIN WIRE : Electrolytic, tinned, stranded, copper drain wire along each pair.
5- INDIVIDUAL SCREEN : Aluminium tape screen over each pair & drain-wire bunch (100% coverage). Layup : Pairs laid up concentrically.
6- SEPERATOR : Separating foil above screen or inner sheath (on request).
7- OVERAL SCREEN : Electrolytic copper braided screen (90% coverage). Aluminium tape + drain-wire overall screen on request (100% coverage). 8- OUTER SHEATH : Halogen-free, flame retardant, thermoplastic polyolefin based compound (HM4 / SHF1) - HD 604. Color: Black or Grey.
PRODUCTION AND TEST STANDARDS
CONSTRUCTION : IEC 60092/376
TESTS AND MATERIAL : IEC 60092 /350-351-359
FLAME RETARDATION : IEC 60332 /1, IEC 60332 / 3
HALOGEN CONTENT : IEC 60754 / 1 - 2
SMOKE DENSITY : IEC 61034 / 1-2 ( DIN EN 50268/1-2)
WORKING TEMPERATURE : -40°C / + 90°C
MIN. BENDING RADIUS (FIXED) : 12 x ( Overall Diameter)
RATED VOLTAGE : 60/250 kV
TEST VOLTAGE : 1,5 kV
APPLICATION
Used as control and communication cables in radio, radar and information systems of marine vehicles. Its twisted pairs enables proper transmission of high frequency signals, while its overall screen and individual screens minimizes electromagnetic interference both environmentally and individually.
作為海洋車輛無線電,雷達和信息系統控制和通信電纜。其“雙絞線使高頻信號的正確傳輸,而其”整體畫面和各個屏幕既環保且單獨最小化電磁干擾。
ENVIRONMENT
Usable at all conditions in marine environment such as dry, wet or oily locations, inside the engine room, where maximum electro-magnetic protection is required as well.
SAFETY
Due to its halogen-free, low smoke density and flame retardant features, it wont create corrosive gases nor obstruct visibility and prevents the fire from spreading around. Thus it protects human life and equipment, during a fire.