MGCH - MGCH (EMC)
HALOGEN - FREE, FLAME RETARDANT, SCREENED POWER CABLE
CABLE STRUCTURE
1- CONDUCTOR : Electrolytic, stranded, annealed copper wire. IEC 60228 Class 2 (Class 5 and/or tinned on request).
2- INSULATION : HF HEPR compound.
3- BEDDING : Halogen free compound.
4- SCREEN : Electrolytic copper braided screen (90% coverage). MGCH (EMC) type is wrapped by a copper tape in addition to this screen (100% coverage).
5- OUTER SHEATH : Halogen-free, flame retardant, thermoplastic polyolefin based compound (HM4 / SHF1) - HD 604. Color: Black or Grey.
PRODUCTION AND TEST STANDARDS
CONSTRUCTION : DIN 89158, IEC 60092/353
TESTS AND MATERIAL : IEC 60092 /350-351-359
FLAME RETARDATION : IEC 60332 /1, IEC 60332 / 3
HALOGEN CONTENT : IEC 60754 / 1 - 2
SMOKE DENSITY : IEC 61034 / 1-2 ( DIN EN 50268/1-2)
SHIELDING EFFECTIVENES (for EMC type) : DIN EN 50147-1
WORKING TEMPERATURE : -40°C / + 90°C
MIN. BENDING RADIUS (FIXED) : 8 x (Overall Diameter)
RATED VOLTAGE : 0,6 / 1 kV
TEST VOLTAGE : 3,5 kV
APPLICATION
Used as fixed installation cables in various electromechanical and electronic equipments of marine vehicles. Due to its overall screen, environmental electromagnetic interference is minimized.
ENVIRONMENT
Usable at all conditions in marine environment such as dry, wet or oily locations.
SAFETY
Due to its flame retardant feature, the part which directly contacts with fire will burn but the flame will not spread along the cable length. Thus it prevents the fire from spreading around.