商品編號: UNTL-FM2XCY-FR
FM2XCY-FR FLAME RETARDANT, XLPE / PVC COMMUNICATION AND SIGNAL CABLE 阻燃,防油,銅網屏蔽船舶用通信和信號電纜 |
|
|
|
|
|
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
|
|
|
FM2XCY-FR
FLAME RETARDANT, XLPE / PVC COMMUNICATION AND SIGNAL CABLE
CABLE STRUCTURE
1- CONDUCTOR : Electrolytic, stranded, annealed copper wire IEC 60228 Class 2 (Class 5 and/or tinned on request).
2- INSULATION : Crosslinked polyethylen compound (XLPE). Layup : Cores laid up in pair, pairs laid up concentrically.
3- SEPARATOR : Separating foil below screen.
4- SCREEN : Electrolytic copper braided screen (90% coverage).
5- OUTER SHEATH : Flame retardant and oil resistant PVC based compound. (ST2). Color : Dark Grey.
PRODUCTION AND TEST STANDARDS
CONSTRUCTION : IEC 60092/353 T
TESTS AND MATERIAL : IEC 60092 /350-351-359
FLAME RETARDATION : IEC 60332 /1, IEC 60332 / 3
WORKING TEMPERATURE : -20°C / + 90°C
MIN. BENDING RADIUS (FIXED) : 8 x (Overall Diameter)
RATED VOLTAGE : 60 / 250 V
TEST VOLTAGE : 1,5 kV
APPLICATION
as control and communication cables in radio, radar and information systems, placed deck blow of marine vehicles. Its twisted pairs enables proper transmission of high frequency signals, while its overall screen minimizes electromagnetic interference environmentally.
ENVIRONMENT
Usable at all conditions in marine environment such as dry, wet or oily locations.
SAFETY
Due to its flame retardant feature, the part which directly contacts with fire will burn but the flame will not spread along the cable length. Thus it prevents the fire from spreading around.
|