    FM2XCH HALOGEN-FREE, FLAME RETARDANT, COMMUNICATION AND SIGNAL CABLE 無鹵,阻燃,防火,雙屏蔽船舶用通信和信號電纜
    看原圖
    30197499




    商品編號: UNTL-FM2XCH

    FM2XCH HALOGEN-FREE, FLAME RETARDANT, COMMUNICATION AND SIGNAL CABLE 無鹵,阻燃,防火,雙屏蔽船舶用通信和信號電纜



    ★★★★商品說明★★★★

    FM2XCH

    HALOGEN-FREE, FLAME RETARDANT, COMMUNICATION AND SIGNAL CABLE

    CABLE STRUCTURE

    1- CONDUCTOR : Electrolytic, stranded, annealed copper wire. IEC 60228 Class 2 (Class 5 and/or tinned on request).

    2- INSULATION : Halogen free, crosslinked polyethylene compound (XLPE). Layup : Cores laid up in pair, pairs laid up concentrically.

    3- SEPERATOR : Separating foil or halogen-free bedding compound on request.

    4- SCREEN : Electrolytic copper braided screen (90% coverage).

    5- OUTER SHEATH : Halogen-free, flame retardant, thermoplastic polyolefin based compound (HM4 / SHF1) - HD 604. Color: Black or Grey.

    PRODUCTION AND TEST STANDARDS
    CONSTRUCTION : IEC 60092/375 - 376

    TESTS AND MATERIAL : IEC 60092 /350-351-359

    FLAME RETARDATION : IEC 60332 /1, IEC 60332 / 3

     HALOGEN CONTENT : IEC 60754 / 1 - 2 ,

    SMOKE DENSITY : IEC 61034 / 1-2 ( DIN EN 50268/1-2)

    WORKING TEMPERATURE : -40°C / + 90°C

    MIN. BENDING RADIUS (FIXED) : 8 x (Overall Diameter)

    RATED VOLTAGE : 60 / 250 V

     TEST VOLTAGE : 1,5 kV

    APPLICATION

    Used as control and communication cables in radio, radar and information systems of marine vehicles. Its twisted pairs enables proper transmission of high frequency signals, while its overall screen minimizes environmental electromagnetic interference.

    ENVIRONMENT

    Usable at all conditions in marine environment such as dry, wet or oily locations, inside the engine room, where electromagnetic protection is required as well.

    SAFETY

    Due to its halogen-free, low smoke density and flame retardant features, it wont create corrosive gases nor obstruct visibility and prevents the fire from spreading around. Thus it protects human life and equipment, during a fire.