1. Kabel-Cables according to Foreign Standards
    Kabel-Compensating Cables and Heatresistant 補償導線耐熱線
    Kabel-Halogen-Free Cables無鹵素電線電纜
    Kabel-Installation Cables and Single Cores 歐規VDE控制電纜線
    Kabel-Marine Cable
    Kabel-OFF-SHORE CABLES 海上平台電纜
    Kabel-VDE Wire & Cable 電線電纜
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > Kabel-Marine Cable

    FM2XCY-FR FLAME RETARDANT, XLPE / PVC COMMUNICATION AND SIGNAL CABLE 阻燃,防油,銅網屏蔽船舶用通信和信號電纜
    看原圖
    30197511



     
      商品編號: UNTL-FM2XCY-FR

    FM2XCY-FR FLAME RETARDANT, XLPE / PVC COMMUNICATION AND SIGNAL CABLE 阻燃,防油,銅網屏蔽船舶用通信和信號電纜
     
       
     

     
       
    ★★★★商品說明★★★★
     
     

    FM2XCY-FR

    FLAME RETARDANT, XLPE / PVC COMMUNICATION AND SIGNAL CABLE

    CABLE STRUCTURE
    1- CONDUCTOR : Electrolytic, stranded, annealed copper wire IEC 60228 Class 2 (Class 5 and/or tinned on request).

    2- INSULATION : Crosslinked polyethylen compound (XLPE). Layup : Cores laid up in pair, pairs laid up concentrically.

    3- SEPARATOR : Separating foil below screen.

     4- SCREEN : Electrolytic copper braided screen (90% coverage).

    5- OUTER SHEATH : Flame retardant and oil resistant PVC based compound. (ST2). Color : Dark Grey.

    PRODUCTION AND TEST STANDARDS

    CONSTRUCTION : IEC 60092/353 T

    TESTS AND MATERIAL : IEC 60092 /350-351-359

    FLAME RETARDATION : IEC 60332 /1, IEC 60332 / 3

    WORKING TEMPERATURE : -20°C / + 90°C

    MIN. BENDING RADIUS (FIXED) : 8 x (Overall Diameter)

    RATED VOLTAGE : 60 / 250 V

    TEST VOLTAGE : 1,5 kV

     
    APPLICATION

    as control and communication cables in radio, radar and information systems, placed deck blow of marine vehicles. Its twisted pairs enables proper transmission of high frequency signals, while its overall screen minimizes electromagnetic interference environmentally.

    ENVIRONMENT

    Usable at all conditions in marine environment such as dry, wet or oily locations.

    SAFETY

    Due to its flame retardant feature, the part which directly contacts with fire will burn but the flame will not spread along the cable length. Thus it prevents the fire from spreading around.