Combined control and supply line for servo motors with UL AWM approval Multi-Standard= less part varieties= cost savings Application rangeDesigned especially to connect SEW servo motors. Connecting cable between servo controler and motor Plant engineering machine tools Printing machines 玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行 ★★★★商品說明★★★★ Technical DataCore identification codePower: black cores with white letters U, VV, WWW and 1 core gnyeControl cores: black cores with white numbers 1, 2 and 3ApprovalsUL-AWM-Style 2570 Based onVDE 0250, 0281 Specific insulation resistance> 20 GOhm x cm Conductor strandingFine wire according to VDE 0295 Class 5/ IEC 60228 Class 5Minimum bending radiusOccasional flexing: 15 x cable diameterStatic: 4 x cable diameter Rated voltagePower cores: IEC 750V, UL 600VControl cores: 1mm² and 1,5mm: IEC 350V, UL 600V Test voltage2000 VProtective conductorG = with protective conductor GN/YE Range of temperatureFlexing: -10°C up to +80°CFixed installation: -40°C up to +80°CDesignFine strands of bare copper wires Core insulation: TPE Control core-triplet screened with laminated aluminium foil and tinned copper wire layer Cores twisted in short lay lengths tinned copper braid PVC outer sheath, orange (RAL 2003) Approvals (Norm references)USA: Acc. NFPA79 Ed 08 in industrial machinery as part of a listed assembly only. Product featuresFor fixed installation or occasionally moved use. Oil resistant Flame retardant according to IEC 60332-1-2 Flame retardant according to UL VW1 / CSA FT1 Part numberNumber of cores and mm² per conductorOuter diameter in mmCopper index kg/kmWeight kg/km  00380604 G 1,5 + (3 x 1,0)11,815130000380614 G 2,5 + (3 x 1,0)13,4212.937000380624 G 4 + (3 x 1,0)15281.847600380634 G 6 + (3 x 1,5)17392.862500380644 G 10 + (3 x 1,5)20625.11024Footnote:All product related values as shown are nominal values unless specified differently. Further values, e.g. tolerances we submit on request - if available and released for publication.Copper price basis: EUR 150 / 100 kg; For utilization and definition of ''Metal price basis'' and ''Metal index'' see Appendix T17Packaging size: Coil ≤ 30">
  1. LAPP- Control Cabinet Single Cores工業級連接線
    LAPP- Expanded ambient temperatures-1工業級超柔耐熱連接線
    LAPP- Expanded ambient temperatures-2工業級超柔耐熱連接線
    LAPP- ÖLFLEX® Conveyor technology工業級連接線
    LAPP- ÖLFLEX® Harsh use conditions 工業級連接線
    LAPP- Servo applications- power drive systems
    LAPP-Building Installation
    LAPP-ÖLFLEX® Harnessed cables 1
    LAPP-ÖLFLEX® Harnessed cables 2
    LAPP-ÖLFLEX® Power chain applications
    LAPP-OLFLEX®-Power and Control Cables -Wide range use(PVC halogen-free)
    LAPP-OLFLEX®-Power and Control Cables -Wide range use(PVC)
    LAPP-Servo applications - power drive systems approved
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > LAPP- Servo applications- power drive systems

    LAPP-SERVO Cables in acc. to SEW® Standard   工業級(伺服馬達)總隔離連接線 Combined control and supply line for servo motors with UL AWM approval
    看原圖
    5316551




    商品編號: LAPP-OLFLEX-SERVO-acc-SEW

    LAPP-SERVO Cables in acc. to SEW® Standard 工業級(伺服馬達)總隔離連接線 Combined control and supply line for servo motors with UL AWM approval


    SERVO Cables in acc. to SEW® Standard  

    Combined control and supply line for servo motors with UL AWM approval

     Multi-Standard= less part varieties= cost savings

    Application range

    • Designed especially to connect SEW servo motors.
    • Connecting cable between servo controler and motor
    • Plant engineering
    • machine tools
    • Printing machines



    ★★★★商品說明★★★★

    Technical Data

    Core identification code
    Power: black cores with white letters U, VV, WWW and 1 core gnye
    Control cores: black cores with white numbers 1, 2 and 3
    Approvals
    UL-AWM-Style 2570
    Based on
    VDE 0250, 0281
    Specific insulation resistance
    > 20 GOhm x cm
    Conductor stranding
    Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5
    Minimum bending radius
    Occasional flexing: 15 x cable diameter
    Static: 4 x cable diameter
    Rated voltage
    Power cores: IEC 750V, UL 600V
    Control cores: 1mm² and 1,5mm: IEC 350V, UL 600V
    Test voltage
    2000 V
    Protective conductor
    G = with protective conductor GN/YE
    Range of temperature
    Flexing: -10°C up to +80°C
    Fixed installation: -40°C up to +80°C

    Design

    • Fine strands of bare copper wires
    • Core insulation: TPE
    • Control core-triplet screened with laminated aluminium foil and tinned copper wire layer
    • Cores twisted in short lay lengths
    • tinned copper braid
    • PVC outer sheath, orange (RAL 2003)

    Approvals (Norm references)

    • USA: Acc. NFPA79 Ed 08 in industrial machinery as part of a listed assembly only.

    Product features

    • For fixed installation or occasionally moved use.
    • Oil resistant
    • Flame retardant according to IEC 60332-1-2
    • Flame retardant according to UL VW1 / CSA FT1