    Caledonian-Thermocouple-EX  Thermocouple Cable EX, JX, KX, TX  600V, 90oC Wet or Dry 歐規補償導線
    看原圖
    5155220




    商品編號: Caledonian-Thermocouple-EX

    Caledonian-Thermocouple-EX Thermocouple Cable EX, JX, KX, TX 600V, 90oC Wet or Dry 歐規補償導線



    ★★★★商品說明★★★★

    Thermocouple Cable EX, JX, KX, TX
    600V, 90oC Wet or Dry


    Application:
    For use as a 600 Volt, multi-pair thermocouple instrumentation cable where flame-retardance, and moisture/chemical resistance is critical. Cable can be installed in free air, in raceways, or direct burial. The cable is also approved for wet or dry locations as well as Class 1 Division II industrial hazardous locations per NEC 501-4(b) for (UL) Type Tray Cables (TC).
    Temperature rating of 90oC wet or dry. Insulation provides excellent electrical, thermal, and physical properties, excellent flame resistance and resistant to crush, compression, cuts and heat deformation. Also conductor insulation provides good low temperature (-40oC) cold bend characteristics.
    Approved for direct burial.

    Construction:
     
  3. Conductor is thermocouple alloy per ANSI MC96.1 - 1982.
  4. Extruded flame-retardant ethylene propylene rubber (EPR) insulation.
  5. Conductors twisted together with a drain wire and aluminum mylar shield. Shielded pairs cabled together with fillers as needed to form a round core. An overall aluminum mylar shield and drain wire is applied over the core.
  6. Pairs are color coded per thermocouple type with pair number printed on the negative (red) conductor. See chart below for specific color codes.
  7. Black, flame-retardant, sunlight resistant, Chlorinated Polyethylene (CPE) jacket. Available with color coded jacket.
  8. Available with class B stranding per ASTM B174.

    Standards:
     
  9. Insulated Conductor - VW-1.
  10. UL Type TC, 90oC Wet or Dry, 600V
  11. ICEA S-82-552, 90oC Wet or Dry, 600V.
  12. Passes UL 1277 Flame Test (70,000 BTU/hr).
  13. Passes UL 1202 Flame Test (70,000 BTU/hr).
  14. Passes IEEE 383 Flame Test (70,000 BTU/hr).
  15. Passes ICEA T-29-520 Flame Test (210,000 BTU/hr).

    EX - Color Code
  16. Chromel (Positive) - PURPLE
  17. Constantan (Negative) - RED

    JX - Color Code
  18. Iron (Positive) - WHITE
  19. Constantan (Negative) - RED

    TX - Color Code
  20. Copper (Positive) - BLUE
  21. Constantan (Negative) - RED

    KX - Color Code
  22. Chromel (Positive) - YELLOW
  23. Alumel (Negative) - RED
     
  24. Item #

    Number of
    Shielded Pairs

    Insulation Thickness
    (mils)

    Jacket Thickness
    (mls)

    Overall
    Diameter
    (inches)

    Weight
    LBS/MFT

    ITC-20-1 1 0.025 0.045 0.270 35
    ITC-20-2 2 0.025 0.045 0.035 70
    ITC-20-3 3 0.025 0.045 0.450 85
    ITC-20-4 4 0.025 0.045 0.500 105
    ITC-20-6 6 0.025 0.045 0.600 160
    ITC-20-8 8 0.025 0.045 0.670 210
    ITC-20-10 10 0.025 0.045 0.735 240
    ITC-20-12 12 0.025 0.045 0.790 280
    ITC-20-16 16 0.025 0.045 0.890 360
    ITC-20-24 24 0.025 0.045 1.060 500
    ITC-18-1 1 0.025 0.045 0.300 50
    ITC-18-2 2 0.025 0.045 0.480 90
    ITC-18-3 3 0.025 0.045 0.510 115
    ITC-18-4 4 0.025 0.045 0.595 165
    ITC-18-6 6 0.025 0.045 0.670 220
    ITC-18-8 8 0.025 0.045 0.750 280
    ITC-18-10 10 0.025 0.045 0.820 340
    ITC-18-12 12 0.025 0.045 0.930 430
    ITC-18-16 16 0.025 0.045 1.045 540
    ITC-18-24 24 0.025 0.045 1.235 760
    ITC-16-1 1 0.025 0.045 0.325 60
    ITC-16-2 2 0.025 0.045 0.570 130
    ITC-16-3 3 0.025 0.045 0.600 160
    ITC-16-4 4 0.025 0.045 0.660 200
    ITC-16-6 6 0.025 0.045 0.740 270
    ITC-16-8 8 0.025 0.045 0.880 380
    ITC-16-10 10 0.025 0.045 0.970 460
    ITC-16-12 12 0.025 0.045 1.035 530
    ITC-16-16 16 0.025 0.045 1.165 570
    ITC-16-24 24 0.025 0.045 1.400 960