1. RFS-Parts RF 電纜 配件
    RFS-RF同軸電纜Low-Loss Foam-Dielectric Coaxial Cable
    RFS-RF洩波 電線電纜 RADIAFLEX® RAY Cable
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > RFS-RF洩波 電線電纜 RADIAFLEX® RAY Cable

    RFS-RCF12-50JFN 低煙無鹵漏波電纜 1/2" RADIAFLEX® RCF Cable
    看原圖
    RFS-RCF12-50JFN

    商品編號: RFS-RCF12-50JFN

    RFS-RCF12-50JFN 低煙無鹵漏波電纜 1/2" RADIAFLEX® RCF Cable

     
    • Broadband from 30 MHz to 6000 MHz
    • Physical properties similar to the CELLFLEX® cable family of type LCF
    • Robust cable
    • Low bending radii
    • Main applications: in-building, vehicles, mines
    • Meets MSHA requirements for US mining applications
     
       
    Product Description

    RADIAFLEX® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas.

    Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Conversely, a signal transmitted near the cable will couple into the slots and be carried along the cable length.

    RADIAFLEX® is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.

    This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a corrugated copper outer conductor which offers a combination of remarkable flexibility, high strength and excellent electrical performance.

    Features/Benefits
    • Broadband from 30 MHz to 6000 MHz
    • Physical properties similar to the CELLFLEX® cable family of type LCF
    • Robust cable
    • Low bending radii
    • Main applications: in-building, vehicles, mines
    • Meets MSHA requirements for US mining applications

    RCF cable
    Technical Specifications
    Size [ in ] 1/2"
    Maximum Frequency [ MHz ]  6000
    Cable Type RCF
    Jacket JFN: halogen free, non corrosive, flame retardant, low smoke, polyolefin
    Test methods for fire behaviour of cable :
    IEC 60754-1/-2 smoke emission: halogen free, non corrosive
    IEC 61034 low smoke
    IEC 60332-1 flame retardant
    Slot Design Milled (Two-Row)
    Previous Model Number  
    Impedance [ Ω ] 50 +/-2
    Velocity [ % ] 88
    Capacitance [pF/m (pF/ft)] 76 (23.2)
    Inductance [ µH/m (µH/ft)] 0.190 (0.058)
    Inner Conductor dc Resistance [ Ω/km (1000 ft) ] 1.57 (0.48)
    Outer Conductor dc Resistance [ Ω/km (1000 ft) ] 2.23 (0.68)
    Outer Conductor Material:  Corrugated Copper Tube
    Inner Conductor Material:   Copper Clad Aluminum Wire
    Diameter over Jacket [ mm (in) ] 16.2 (0.64)
    Diameter Outer Conductor: [ mm (in) ] 13.8 (0.54)
    Diameter Inner Conductor: [ mm (in) ] 4.8 (0.19)
    Minimum bending radius, single bending [ mm (in) ] 125 (4.9)
    Cable Weight [ kg/m (lb/ft) ] 0.26 (0.17)
    Max. tensile force [ N (lb) ] 1000 (225)
    Indication of Slot Alignment None
    Storage temperature [ °C (°F) ] -70 to +85 (-94 to +185)
    Installation temperature [ °C (°F) ] -25 to +60 (-13 to +140)
    Operation temperature [ °C (°F) ] -40 to +85 (-40 to +185)
    Stop band [ MHz) ] None
    Recommended / maximum clamp spacing [ m (ft) ] 0.6 (2.0)
    Minimum Distance to Wall [ mm (in) ] 50 (2)
    Length [ m (ft) ]  
    Rev. Number 2008/08/26
     
    Table of Losses

     
    Frequency, MHz Longitudinal Loss, dB/100 m (dB/100 ft) Coupling Loss 50%, dB Coupling Loss 95%, dB
    75 2,20 (0,67) 50 62
    150 3,15 (0,96) 59 71
    450 5,70 (1,74) 67 79
    800 7,83 (2,39) 67 79
    870 8,25 (2,51) 66 79
    900 8,40 (2,56) 66 78
    960 8,65 (2,64) 66 78
    1800 13,1 (3,99) 68 80
    1900 13,6 (4,15) 69 81
    2000 14,0 (4,27) 72 84
    2200 14,7 (4,48) 70 82
    2400 15,3 (4,66) 70 82
    2600 15,9 (4,85) 70 82
    5000 24,8 (7,56) 75 87
    5200 25,7 (7,83) 75 87
    5800 27,6 (8,41) 75 87
    6000 29,9 (8,81) 75 87
    Standard conditions
     
    Notes

    Coupling loss as well as longitudinal attenuation of RADIAFLEX® cables are measured by the free space method according to IEC 61196-4.

    • Coupling loss values are average values of all three spatial orientations (radial, parallel and orthogonal) of dipole antenna.

    • Coupling loss values are given with a tolerance of ±10 dB and longitudinal loss values with a tolerance of ±5%.

    • As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method.